9. POWER ON/OFF
PROCEDURE Power ON
1. Press
{
}
.
When the power is switched on, the Tilt screen is
displayed.
Press
{ESC}
to go to top menu.
If "Out of range" is displayed, the instrument tilt
sensor is indicating that the instrument is out of level.
Level the instrument once again using circular level,
then the tilt screen will be displayed.
$
• "Tilt crn." in "Obs. condition" should be set to "No" if the display is unsteady due to vibration or strong
wind.
C
&
Resume function
The Resume function redisplays the screen appearing before the instrument was powered OFF
when the instrument is powered back ON. All parameter settings are also saved. Even if
remaining battery power is completely depleted, this function will remain active for 1 minute,
after which it is canceled. Replace a depleted battery as soon as possible.
PROCEDURE Power OFF
Press
{
}
and hold (about 1sec).
G
• When there is almost no battery power remaining,
the battery mark in the status bar will start to
blink.In this event, stop measurement, switch off
the power and charge the battery or replace with a
fully charged battery.
• To save power, power to the FX is automatically cut
off if it is not operated for a fixed period of time. This
time period can be set in "Power off" in
<Inst.config.>.