77
16. SETTING-OUT MEASUREMENT
I
Guide light status and meaning
Indication for positioning target during setting-out measurement
The point is to be found based on the horizontal angle from the reference direction and the distance
from the instrument station.
Light status
Meaning
Increased flashing speed
(From position of poleman) Move target toward FX
Decreased flashing speed
(From position of poleman) Move target away from FX
Fast flashing
Target is at correct distance
Red
(From position of poleman) Move target left
Green
(From position of poleman) Move target right
Red and Green
Target is at correct horizontal position
16.2
Distance Setting-out Measurement