21.WARNING AND ERROR MESSAGES
The following is a list of the error messages displayed by the FX and the meaning of each message.
If the same error message is repeated or if any message not shown below appears, the instrument
has malfunctioned. Contact your local dealer.
Backup battery dead. Clock display may no longer be correct.
The voltage supplied by the lithium battery either declines or is completely discharged. Ask your
local dealer to replace the battery for you.
Bad condition
The air is shimmering a lot, etc., measuring conditions are poor.
The center of the target cannot be sighted.
Resight the target.
Unsuitable distance measurement conditions when reflectorless measurement is set. When
reflectorless measurement is set, distance cannot be measured because the laser beam is
striking at least two surfaces at the same time.
Choose a single surface target for distance measurement.
C
Precautions for setting prism: "11. FOCUSSING AND TARGET SIGHTING"
Calculation error
During resection measurement the same point is registered multiple times. Set another known
point so that the known point coordinates do not coincide.
Coordinates identical to the known point coordinates observed during resection exist.
During surface area calculation, conditions necessary for calculations are not met. Check
conditions and try again.
An error occurred during calculation.
Device list is full !!
No more
Bluetooth
devices can currently be registered. Delete unnecessary devices from the list
and try again.
Error: Read Build Info.
Error: Read sysflg
Error: Self check
Error: Read OS Parameter
Error: Write sysflg
Press
[OK]
to cancel the message. If this error message appears frequently, contact your local
dealer.
Incorrect password.
Input password does not match set password. Input correct password.
Input device name !!
Bluetooth
device name not input. Input device name and complete device registration.