background image

 

 

16

Test the Reversing Sensitivity 

For the sake of safety, it is very important to test the reversing sensitivity as soon as the control board set is 

finished. 

The reversing sensitivity adjustment is inverse correlation with stall force adjustment in potentiometer A and 

B. In other word, the stall force level is higher; the reversing sensitivity level is lower. 

Put an immobile object along the gate path, and then operate the gate to strike it during the close cycles. The 

gate must reverse as soon as object is struck with it. If the gate doesn

t reverse, please increase the reversing 

sensitivity by turning the potentiometer in counter-clockwise direction. (Turning the stall force potentiometer 

toward to MIN position to increase the reversing sensitivity) 

Note 1: If the sensitivity setting is too higher, the gate will stop or reverses very easy by itself while 

there is little obstruction or resistance such as strong wind or heavy snow sometimes. 

Note 2: Always check the gate reversing function every each time of control board set or restart after 

power off. 

 

 

How to Program or Erase the Remote 

†  

The remote MUST be programed to the opener BEFORE OPERATING. Please follow the steps to 

program the remote. 

†  

Activate the opener only when gate is in full view, free of obstruction and properly adjusted. No 

one should enter or leave gate area while gate is in motion. DO NOT ALLOW CHILDREN to operate 

push button or remote. DO NOT ALLOW CHILDREN TO PLAY NEAR THE GATE. 

†  

If you purchase additional remote controls, the gate opener must be programmed to accept the 

new remote code. 

†  

If you lose one of any remote control, please erase and reprogram all other remote controls to 

have a new code for safety. 

†  

 

Program the remote 

Press and release the learn button, the 

REM

 

LED

 light 

will be on, then press the key in the remote 

two times

 in 

2 seconds, 

between the two times HOLD ON FOR A 

MOMENT

, the 

REM LED

 light will flash for 4 seconds. 

Now the remote has been programmed successfully. 

 

Erase all the remote codes 

Press and hold the learn button until the 

REM

 

LED

 light is off. Now all remote codes have been erased. 

†  

NOTE:

 

Max. 8 remotes can be programmed for the opener. An External Receiver (optional) allows up to 

250pcs  remotes  to  be  programmed  for  the  opener.  TOPENS  ERM12  Universal  External  Receiver  is 

available at TOPENS Store.   

†  

TOPENS ERM12 Universal External Receiver is also compatible with other brand swing gate opener, 

sliding gate opener and garage door opener. 

 

 

 

Summary of Contents for DKC500

Page 1: ...support topens com DKC500 S Y Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the ba...

Page 2: ...com Amazon ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Coun...

Page 3: ...rts 5 Technical Specifications Features 6 Installation Overview 6 Installation of the Opener 7 Manual Operation 7 Installation of chain and chain brackets 8 Installation of the Magnets 9 Connection of...

Page 4: ...product and be dangerous The factory declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the prese...

Page 5: ...l moving part as well as the sliding gate is in good mechanical condition correctly balanced and opens and closes properly Save these instructions for future use Preparation for Installation Before pr...

Page 6: ...3 In sake of safety a positive stop must be mounted on the two end of ground track...

Page 7: ...4 Parts List Extra Parts...

Page 8: ...75P Wired Keypad TEW3 Vehicle Sensor Exit Wand HLR01 HomeLink Remote Control Kit TC173 Wireless Push Button TC147 Wired Push Button TRF3 Reflection Photocell Sensor TC102 Photo Eye Beam Sensor JD24VY...

Page 9: ...rection Reliable rolling code technology for remote control Emergency release key in case of power failure Stop in case of obstruction during gate opening Reverse in case of obstruction during gate cl...

Page 10: ...ase the pad height if necessary to protect the system from flooding heavy snow etc 3 Prepare one or more conduits for the electrical cables before pour concrete Remember that cable conduits have to pa...

Page 11: ...under the drive sprocket in chain box 2 Connect a chain bolt to one end of chain from chain box by using master link Then insert the chain bolt to the L bracket and fix them each other by washers and...

Page 12: ...tion the clutch connected with gear shaft is disengaged and the mains power supply is disconnected Position the two Magnet Components approximately on the gate and move the gate by hand to fix them in...

Page 13: ...ed in series to function as 24VDC The following diagram shows on how to connect 2 PCS batteries in series 3 Please note that the wire connection of the power supply system is very important Incorrect...

Page 14: ...ries photocell external receiver exit wand and keypad Please provide us with more details of the local sunshine condition and accessories needs which we can calculate the configuration of the solar pa...

Page 15: ...12 Connecting of the Control Board...

Page 16: ...l of the photocell s emitter to the 19 terminal the terminal to the 18 terminal Also the and terminals of the photocell s receiver should be connected to the 19 and 18 terminals in parallel Use anothe...

Page 17: ...big power of solar panel is required if you want to use any one of them If the batteries and solar panel is used as main power supply Setting of the Control Board WARNING Ensure the gate opener is Po...

Page 18: ...tch 7 ON 60 Seconds OFF 0 NOTE The auto close function would be disabled if both DIP switches are turned to off factory default setting Important Note When the auto close function is enabled the photo...

Page 19: ...ed to the opener BEFORE OPERATING Please follow the steps to program the remote Activate the opener only when gate is in full view free of obstruction and properly adjusted No one should enter or leav...

Page 20: ...you may program either C button or D button with TOPENS swing gate opener Wireless Keypad Programming You can follow the below steps to program wireless keypad to the opener Press the Learn button unt...

Page 21: ...vention device If a photocell is not used photocell terminal of the control board should be shorted by a jumper wire 2 Check the motor Release the clutch then disconnect the wires of the motor from te...

Page 22: ...and check that the gate slides freely without any binding 5 Check the control board Replace the control board if necessary The gate opens but stops and will not return 1 Please note the two limit magn...

Page 23: ...ld you have any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site O...

Reviews: