20
2. Force set too low. Adjust FORCE setting until gate completes a full open/close cycle without stop. The force
setting may need to be adjusted in cold weather, as the gate will not move freely.
3. Check if the MRT period is too short.
◆
Gate opens but does not close.
1. Photocell (PBS) function is enabled in control board setting but is not equipped (optional). Please cancel the
PBS setting (P9 set to 00).
2. Obstruction blocking close photo eyes, Check eyes for alignment and verify all connections and operation for
safety devices.
3. Remove the BLUE&GREEN&YELLOW wires of the arm from the control board and use a jumper wire to
short the ULT&COM&DLT terminals of the control board which for connecting the three wires and then try it
again. The limit switch of the arm is faulty if the arm could run normally.
◆
Gate ignores the limit switches
1. Check that the wires of the limit switch (BLUE&GREEN&YELLOW wires of the arm) are not shorted.
2. Limit switch of the arm is faulty. Replace the limit switch as necessary.
◆
Gate opens, closes or stops on its own
1. Please make sure the wire connection of the arm is according to the installation of “PULL TO OPEN” or
“PUSH TO OPEN”.