background image

21 

NOTE: 

You may need to increase the stall force in cold weather due to increased resistance from 

gate hinges. The gate opener

’s opening/closing force is adjusted automatically according to stall force 

adjustment. 

Note:

  If  the 

“11” is be  set, the gate opener won’t work until the PBS system is equipped. The PBS 

system works only when gate opener is closing. The gate opener will return to its open position when 

the obstruction blocks the beam from photo eye. 

Now stall force of gate opener 1 is finished. 

(Factory set is Level 3) 

6-b Adjust Stall Force of Gate Opener 2   

When the Digital Display indicates 

“P6”.you can adjust force of gate opener 2. 

Please perform the same procedure as gate opener 1 (6-a). 

Press the 

“FUNC” button to store the data when stall force of gate opener 2 is set. Then “P7” will be shown on 

the Digital Display. 

 

 

 

 

7. Adjust the Max Motor Running Time (MRT) of the MOTOR for gate opener 

The maximum running time of the MOTOR can be set to make the motor stop running after a specified period 

even if the limit switch is invalid or the clutch is detached. 

7-a. Adjust the MRT of MOTOR1 

When the Digital Display indicates 

“P7”, you can adjust the 

MRT

 of MOTOR1. 

The 

MRT

 of MOTOR1 is adjusted by pressing 

“INC” and “DEC” buttons respectively. The Digital Display will 

show 

“01”-“50” which indicates the 

MRT

 of MOTOR1 from 1 to 50 seconds. 

You can hold pressing the 

“INC” or “DEC” button for more than 1 second to speed up the setting. Press the 

“FUNC” button to store the data when you finish setting. The Digital Display will indicate “P8”. 
(Factory default setting is 

“40” seconds) 

7-b. Adjust the MRT of MOTOR2 

When the Digital Display indicates 

“P8”, you can adjust the 

MRT

 of MOTOR2. 

Please perform the same procedure as adjusting MOTOR1 (7-a). 

Press the 

“FUNC” button to store the data when you finish setting. The Digital Display will indicate “P9”. Now 

MOTOR2 adjustment is finished. 

8. Set the Safety Photocell Beam System (PBS) (Optional) 

When the Digital Display indicates 

“P9”, the gate opener enters PBS set mode. 

You can press and release the 

“INC” or “DEC” button to set or shut off the PBS function. The Digital Display 

indicates 

“11”, the PBS is available. The Digital Display indicates “00”, the PBS is null.   

 

 

 

     

Press the 

“FUNC” button to store the data when the PBS is set. The Digital Display will indicate “PA”. 

(Factory set is 

“00”)   

9. Set the Automatic Closing Time 

When the Digital Display indicates 

“PA”, the gate opener enters into the setting of automatic closing time mode. 

Press  and  release  the 

“INC”  or  “DEC”  button,  the  Digital  Display  will  show  a  “01”-“99”  which  indicates  the 

current automatic closing time. The minimum time is 1 second, 99 seconds maximum. Each time you press and 

release the 

“INC” button, the figure increases by 1, and the timing increases by 1 second. Each time you press 

and  release  the 

“DEC” button, the figure  decreases by 1, and the timing decreases by 1 second. When the 

timing is 

“00”, the automatic closing function is shut off and the gate will stay open. 

(Factory set is 60 seconds) 

Press the 

“FUNC” button to store the data when the desired automatic closing time is set. The Digital Display 

will indicate 

“Pb”. 

Important  Note:  When  the  auto  close  function  is  enabled,  the  photocell  sensor  is  highly 

recommended to be installed with the gate opener for safety.   

 

Summary of Contents for KD902

Page 1: ...ens com VER 21a KD902 Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the battery Per...

Page 2: ...n ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Country Regio...

Page 3: ...for Pull to Open 7 Install the Opener on the Gate for Push to Open 10 Mounting the Control Box 13 Connection of the Power Supply 14 Connecting of the Control Board 15 Motor connection for PUSH TO OPE...

Page 4: ...l be located such that persons will not come in contact with the moving vehicular gate 8 Pedestrians should never cross the pathway of a moving gate The gate opener is not acceptable for use on any pe...

Page 5: ...gate and keep all controls out of their reach NOTE TOPENS Gate Operator can be used for driveway gates made by steel wood vinyl and shaped as panel tube and chain link While use on solid surface gate...

Page 6: ...3 KD902 Parts List Accessories Parts Included in some models refers to the actual package...

Page 7: ...k TRF3 Reflection Photocell Sensor TC102 Photo Eye Beam Sensor JD24VY 24V Warning Light TSP30W 30W Solar Panel Charging Kit TCS3 Solar Charge Controller 25FT Extension 5 Conductor Cable Replacement Pa...

Page 8: ...re subject to change without notice Features Soft start and soft stop Emergency release key in case of power failure Dual Single gate running mode Adjustable opening closing interval between master an...

Page 9: ...ation Overview Pull to Open Gates Important The second gate opener cable should be put into the PVC conduit not provided which is buried underground This protects the cable from lawn mowers and string...

Page 10: ...er size washer or metal plate should be used between the bolts and the wooden post to ensure the stability of the fastening hardware If the post is smaller than 6 diameter or square it should be made...

Page 11: ...he opener fully retracted and with the gate in the fully open position for Pull to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate post and the gate While ho...

Page 12: ...gate post Fasten each bolt with one 10 washer one 10 lock washer and one 10 nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the gate brackets and the drilled holes...

Page 13: ...en The position of Post Bracket is very important The following illustrations and tables are required to determine the proper mounting position for the Post Bracket The tables show the maximum opening...

Page 14: ...erclockwise 4 With the opener fully retracted and with the gate in the fully closed position for Push to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate post...

Page 15: ...gate post Fasten each bolt with one 10 washer one 10 lock washer and one 10 nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the gate brackets and the drilled holes...

Page 16: ...es above the ground to avoid being flooded or buried under snow Step 2 Insert the power cable and cable of the first gate opener through the front strain relief and into the control box by loosening t...

Page 17: ...1 5m length are provided Other cables are subject to site installation requirement and not provided Connection of the Power Supply WARNING NEVER connect the gate opener to the power outlet before all...

Page 18: ...15 Connecting of the Control Board...

Page 19: ...ow wire into DLT2 terminal NOTE It is recommended that Gate Opener 1 is installed in the Master Gate and Gate Opener 2 is installed in the Slave Gate Warning Light Included in some models refers to th...

Page 20: ...be connected into the 9 terminal Wired Keypad 24VDC optional The RED wire of the wired keypad should be connected into the 9 terminal The BLACK wire of the wired keypad should be connected into the 14...

Page 21: ...tely open stop close stop open 2 Use one remote to operate TOPENS swing gate opener sliding gate opener at the same time All of TOPENS sliding gate opener have midway mode Button B is designed to real...

Page 22: ...Always ask the help of professional technician electrician if you have any question 1 Check again for completed and correct assembly of your swing gate opener and gate Plug the Power Cord into the ne...

Page 23: ...and the Master gate starts to open 1 more second earlier Each time you press and release the DEC button the figure decreases by 1 and the interval decreases by 1 second Factory set is 3 seconds Press...

Page 24: ...indicate P8 Factory default setting is 40 seconds 7 b Adjust the MRT of MOTOR2 When the Digital Display indicates P8 you can adjust the MRT of MOTOR2 Please perform the same procedure as adjusting MOT...

Page 25: ...by yourself from the arm actuator starting to move on the fully open position to the arm arriving at the fully close position how can we get 4 sec of Soft Stop Period SPP to meet the requirement The a...

Page 26: ...y a silicone spray to reduce its friction In cold climates where temperatures reach 1 C 30 F or less spray silicone on the actuator every 4 6 weeks to prevent freeze up 2 Regularly check gate hinges t...

Page 27: ...n cold weather as the gate will not move freely 3 Check if the MRT period is too short Gate opens but does not close 1 Photocell PBS function is enabled in control board setting but is not equipped op...

Page 28: ...25 Quick Setting Guide...

Page 29: ...26...

Page 30: ...27...

Page 31: ...28...

Page 32: ...you have any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site Ord...

Reviews: