19
4.3 Setting the Open Force
4.4 Setting the Close Force
1. Press and hold SET button for more than 4 seconds.
The Digital Display indicates “1” (Skip if continuing Open
Force Set after the Limits Set is finished).
2. Continually press UP button until the Digital Display
indicates “3” (Pic.4.3-1). Press and release SET button.
“3” flashes in the Digital Display (Pic.4.3-2). Now the unit
enters into Force Adjustment Mode.
3. Press and release UP button. “1” –“9” flashes in the
Digital Display (default value is “4”) (Pic.4.3-3) which
indicates Open Force level. “1” is the minimum force, and
“9” is the maximum force. Each time press and release
UP button, the figure is bigger by 1, and the force
increases to a higher level. Each time press and release
DOWN button, the figure is smaller by 1, and the force
decreases to a lower level (Pic.4.3-4).
4. Press SET button to store the data when desired Open
Force is set. “3” glows steadily in the Digital Display (Pic.
4.3-5). The unit is ready for setting other parameter.
Press SET button for seconds till “H” appears in Digital
Display (Pic.4.3-6). Now the Open Force Adjustment is
finished.
1. Press and hold SET button for more than 4 seconds.
The Digital Display indicates “1” (Skip if continuing
Close Force Set after the Open Force Set is finished).
2. Continually press UP button until the Digital Display
indicates “4” (Pic.4.4-1). Press and release SET button.
“4” flashes in the Digital Display (Pic.4.4-2). Now the
unit enters into Close Force Setting Mode.
3. Press and release UP button. “1” –“9” flashes in the
Digital Display (default value is “4”) (Pic.4.4-3) which
indicates Close Force level. “1” is the minimum force,
and “9” is the maximum force. Each time press and
release UP button, the figure is bigger by 1, and the
force increases to a higher level accordingly. Each time
press and release DOWN button, the figure is smaller
by 1, and the force decreases to a lower level
accordingly (Pic.4.4-4).
4. Press SET button to store the data when desired
Close Force is set. “4” glows steadily in the Digital
Display (Pic.4.4-5). The unit is ready for setting other
parameter. Press SET button for seconds till “H”
appears in Digital Display (Pic.4.4-6). Now the Close
Force Set is finished.
Summary of Contents for MultiRuta CASAR 800