8
TOPEX.PL
It also causes faster wear of the caliper measurement surfa-
ces..
3. Do not apply voltage (e.g. of electric tester) to any part of the
caliper, it may damage electronic assembly of the caliper.
4. Remove battery from the caliper, when it is not to be used
for a long time.
TECHNICAL PARAMETERS
Measuring range:
0 ÷ 200 mm / 0 ÷ 8 in
Resolution:
0,01 mm / 0,0005 in
Measurement accuracy:
±0,02 mm / ±0,001 in
Maximum measuring speed:
1.5 m/s
Measuring system:
Linear capacitive measuring system
Display:
LCD
Power supply:
Silver oxide (AgO) cell, 1.55V, SR44
type, 180 mAh capacity
Current:
<20 μA
Working temperature range:
5
0
C ÷ 40
0
C
Effect of humidity:
Negligible below relative humidity
equal to 80%
GENERAL OVERVIEW OF CALIPER WITH DIGITAL DISPLAY
(fig. 1)
A. External measurement jaws
B. Internal measurement jaws
C. Depth measurement rod
D. Guide
E. Battery compartment lid
F. Display
G. Slider lock screw
H. Slider shift roller
I. Unit toggle button (mm/inches)
J. Zero adjustment button (ZERO)
K. Slider
L. ON/OFF button
M. ORIGIN function reset button
CALIPER OPERATION
Ensure all caliper surfaces are free from grease, dust, dirt and
filings before starting to use the caliper. Use a cloth to wipe all
measurement surfaces of the caliper before starting to work.
Use of any organic fluid is forbidden. Ensure that all buttons and
LCD display operate correctly.
To make a measurement:
– loosen slider lock screw (fig. 1/G),
– press ON/OFF button (fig. 1/L)
– select desired measurement unit by pressing the unit
toggle button (fig. 1/I) – every time the button is pressed,
measurement units change,
– use the slider shift roller (fig. 1/H) to move the jaws closer;
displayed value (fig. 1/F) should be zero; when it is not so,
press the zero adjustment button (fig. 1/J),
– display can be zeroed at any point within the measurement
range.
Measuring external dimensions (fig. 2)
– Position measured object as close to the guide reference
surface as possible,
– Move measurement jaws to contact outer surfaces of
measured object.
Measuring internal dimensions (fig. 3)
– Slide internal measurement jaws as deep as possible,
– Move measurement jaws to contact inner surfaces of
measured hole.