Shenzhen TOPFLYTECH Co., Limited. All Rights Reserved 12
Range: Positive Integer
Length Limit: 0~65535
Note: Tracker
will return “SET
IP
OK” when received this command.
11.3 Upload Interval Setting
TIMER,
Current PIN,Upload Time(ACC on):Upload Time(ACC off):Angle Compensation:
Distance Compensation#
Upload Time (ACC on):
Range: Positive Integer
Range Limit: 3~65535
Default: 25
Upload Time (ACC off):
Range: Positive Integer
Range Limit: 0~65535
Default: 600
Angle Compensation:
Range: Positive Integer
Range Limit: 0~90 degrees
Default: 30 degrees
Distance Compensation:
Range: Positive Integer
Range Limit: 0 ~ 65535 meters
Default: 0 meters
Note:
Tracker will return “
SET TIMER OK
” when received this command.
11.4 Heartbeat Setting
HBT,
Current PIN,Heartbeat Interval#
Heartbeat Interval:
Range: Positive Integer
Range Limit: 0 ~ 255 minutes
Default: 5 minutes
Note: Tracker will return “SET
HBT
OK” when received this command.
11.5 GMT Setting
GMT
,
Current PIN,Time Zone#