Application Note: Security, Alarm System 

www.topkodas.lt

  

 

13  | 

E N

   

2. 

Go to “Outputs (PGM)” window>  

3. 

Enter the required parameters> 

4. 

If the output is not in used, it should be disabled  

5. 

Press “Write” icon. 

 

Outputs can be set as timers. 

 
 

1. 

When  output  is  activated  for  “Out 
Timer” time interval, 

2. 

Relay  contact  start  changing  state 
from  ON  (pulse  time  ON)  to  OFF 
(Pulse time Off) 

3. 

This cycle will repeat until output is 
deactivated. 

Output signal

Pulse time ON

Pulse time OFF

Pulse time ON

Pulse time OFF

Output state

Output ON

Output OFF

 

 

 

Bell: 

Output  for  connection  of  audible  sounder  (siren).    After  the  alarm 

system actuation a continuous or pulse (fire) signal is generated. 

OFF

ON

Alarm

Bell time

Bell

 

ARM/DISARM: 

Output  for  connection  of  light  indicator  of  the  alarm 

system  status.    When  the  alarm  system  is  on  a  continuous  signal  is 
generated. 

OFF

ON

ARM/DISARM

Open

Close

Open

ARM

DISARM

 

Buzzer: 

Output for connection of audio indicator.  After the alarm system 

activated a pulse signal is generated within Exit Delay time, and continuous 
signal  -  within  Entry  Delay  time  or  when  the  alarm  system  is  disturbed. 
When the alarm system is turned off, operates like keyboard buzzer. 

OFF

ON

Open

Command - ARM

Exit Delay

Close

Entry Delay

Command - DISARM

Buzzer

 

Flash: 

Output for connection of light indicator.  When the alarm system 

is  on,  a  continuous  signals  generated,  and  if  the  alarm  system  is 
disturbed  -  pulse  signal.  Signal  is  terminated  by  turning  off  the  alarm 
system. 

OFF

ON

Flash

Open

Command - ARM

Close

Alarm

Open

 

Remote  Control: 

Output  designed  for  connection  of  electrical  devices 

which will be controlled by SMS message or phone call a) control by SMS 
message 

SMS

OFF

ON

Remote Control 

Pulse 

 

OFF

ON

Remote Control 

Level

SMS 1

SMS 2

 

Remote Control

 b) control by phone call 

 

OFF

ON

Remote Control 

Pulse 

Dial

 

OFF

ON

Remote Control 

Level

Dial 1

Dial 2

 

System State: 

Output for connection of light indicator of the alarm system 

status.  Within Exit  Delay time  a pulse  signal  is  generated,  and  when  the 
alarm system activated 

– continuous. Signal is terminated by turning off the 

alarm system. 

OFF

ON

System State

Open

Exit Delay

Close

Open

 

AC  OK: 

Output  for  connection  of  indicator  about  control  panel  supply 

from alternating current 

OFF

ON

AC OK

AC OK

AC Lost

AC OK

 

Ready: 

Output for connection of light indicator of input statuses. If all zones 

are clear (none violated), a continuous signal is generated. 

OFF

ON

Ready

Zone Fault

Zone OK

 

Battery OK: 

Output for connection of indicator about control panel supply 

from battery. 

OFF

ON

Battery OK

Battery OK

Battery Lost

Battery OK

 

Alarm  indication: 

Output  for  connection  of  light  indicator  showing  alarm 

status of the alarm system.  After the alarm system actuation a continuous 
signal is generated. 

Lost Primary Channel: 

Output where a continuous signal is generated 

when communication with primary channel was lost. 

Summary of Contents for GTalarm2

Page 1: ...GTalarm2 Application Note Security Alarm System Monitoring alarm control This manual includes steps to install set up and use your system...

Page 2: ...PGM outputs 24V 1000mA Open Drain Digital expansion module BUS In field firmware upgrade via USB SERA Cloud Remote Service Events log buffer 2048 events Program remote controls using the master or ins...

Page 3: ...or to the server 1 3 First steps to prepare GTalarm2 module and Sera2 software Preparation procedure of the module GTalarm2 Connect the GSM antenna to the antenna connector Insert the SIM card in the...

Page 4: ...r supply Battery Wiring It is possible to supply the security system from stabilized power supply source 10 15 V and not less than 1 5A It is necessary to calculate max current of power supply The cur...

Page 5: ...sed or used as security system s zones with selectable type NC NO EOL EOL TAMPER 2 programmable analog inputs I O1 I O2 0 10V 0 20mA that can be used or used as security system s zone with selectable...

Page 6: ...Monitoring control via mobile phone web browser GTalarm2 Figure 5 Monitoring control via mobile phone web browser Figure 7 Monitoring via web mobile app Zone status 4 2 Monitoring via SERA2 software...

Page 7: ...Application Note Security Alarm System www topkodas lt 7 E N Figure 8 Monitoring via free Sera2 software Zone status...

Page 8: ...2012 configurable as encrypted and non encrypted Shock sensor Reporting to the central monitoring station GTalarm2 Figure 9 Reporting to the central monitoring station 4 4 Local alarm For protecting...

Page 9: ...able analog inputs I O1 I O2 0 10V 0 20mA for analog sensors control or using as security system s zone with selectable type NC NO EOL EOL TAMPER 5 1 NC NO EOL detectors wiring It is recommended to us...

Page 10: ...owing conditions If a Delay type zone is NOT violated during exit delay and a zone s with Stay attribute enabled exists the system will arm in Stay mode When arming the system in Stay mode under this...

Page 11: ...xcept the module will auto bypass the zone if Armed in the Stay mode 6 Wiring Type Type EOL End of line resistor Input type with resistor NC Normal Close The alarm will be send when the circuit betwee...

Page 12: ...ectors Figure 20 2 wire smoke detector wiring diagram o If I O1 I O2 set as 2 wire don t need connect 5 1k resistor to VD o I O1 I O2 do not have internal pull up resistors So if you want to connect N...

Page 13: ...inuous signals generated and if the alarm system is disturbed pulse signal Signal is terminated by turning off the alarm system OFF ON Flash Open Command ARM Close Alarm Open Remote Control Output des...

Page 14: ...nuous signals generated and if the alarm system is disturbed pulse signal Signal is terminated by turning off the alarm system 25 System State Output for connection of light indicator of the alarm sys...

Page 15: ...arm the system and turn OFF the alarm by dialing the system s phone number from any of 800 available user phone numbers The system ignores any incoming calls from a non listed phone number The phone c...

Page 16: ...smission Delay to enter a valid 4or 6 digits Security Code before the Central Monitoring Center CMS is notified If a valid Security Code is not entered within the 30 seconds then a message is sent to...

Page 17: ...and press Start iButton RFID programming mode to start entering iButton keys 2 Press Stop iButton programming to stop entering iButton keys 3 Write configuration by pressing Write icon C by sending SM...

Page 18: ...elow 9 2 Enter iButton keys by sending SMS message A Send SMS message to the module GTalarm2 INST123456 063 S INST Install Configuration of the parameters 123456 Installer s password Space character 0...

Page 19: ...y In order to delete the code it is necessary to enter 000000000000 7 OUT The selected input will be switched if a user will call from this number Preferred input may be assigned to each user s number...

Page 20: ...t is necessary to enter 000000000000 6 Keyb Code Key button code might be entered manually In order to delete the code it is necessary to enter 000000000000 7 OUT The selected input will be switched i...

Page 21: ...er tamper recognition 18 Tamper Disable The module will not generate an alarm or trouble 19 Trouble when disarmed alarm as per zone when armed When disarmed Generates Trouble Only The module transmits...

Page 22: ...d busy signal b The system will continue dialing the next listed user phone numbers in the priority order The system will dial again as many times as programmed and the same order as phone numbers lis...

Page 23: ...tem can be configured to report events to the monitoring station by transmitting data messages to the monitoring station The system connects to the central monitoring station when the CMS Central Moni...

Page 24: ...station to receive the connection requests TCP mode or the datagrams UDP mode transmitted by ALERT 2 Backup 1 Backup 1 central monitoring station settings 7 Transport Protocol TCP or UDP The used lin...

Page 25: ...Code Format A 4 digit or 6 digit user access code format can be selected 6 I O1 Settings 2 Wire Smoke detector Fire current loop or 0 10V Analog Input Zone or Sensor or Output or 0 20mA 4 20mA Curren...

Page 26: ...ton stops the monitoring of the module 3 IMEI IMEI number of GSM modem available in the module 4 SIM ICCID ICCID Integrated Circuit Card Identifier A SIM card contains its unique serial number ICCID I...

Page 27: ...rm shutdown for the zone is activated Allowable number of the same alarm events is reached and the same events will not be reported 6 Bypassed If checked and the color is red the zone is bypassed 7 Fo...

Page 28: ...seller with the questions about the configuration you have to Press Read icon first to read the configuration from the module the press File Save us and save the configuration Save the Events Log file...

Page 29: ...l be taken to match sensor range to room size A sensor whose range extends well beyond the boundaries of the room is acoustically hot and vulnerable to false alarms For protecting glass on more than o...

Page 30: ...icable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of eac...

Page 31: ...ted on the other side of closed or partly open doors If warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedr...

Reviews: