GTalarm3 User manual V-2022-05-24
25 |
E N
Figure 27 3.4.2.3
[2-Wire] Smoke Detector settings
If you want to edit existing configuration
,
You have to read it (press
“Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)
More information about how to configure 2-Wire Smoke detectors:
I/O1, I/O2 do not have internal pull-up resistors. So if you want to connect NO/NC sensors to I/O1 or I/O2 you have to connect 5.1K
resistor between I/O and +VD
If I/O1 set as 2-
wire, don’t need connect 5.1k resistor to +VD.
3.5
Outputs
The module GTalarm3 has:
4 open drain (1A) outputs:
OUT1 (1A)… OUT4 (1A). The outputs can be used for siren, relay, lamp connection. These outputs can be
controled via short call or sms. Output operation algorithms: Automation /CTRL, Siren, Buzzer, ARM state, Zones OK, Light Flash, inverting,
pulse mode
3 open drain (20mA) outputs:
I/O1 (2
0mA)… I/O3 (20mA). These outputs can be used for solid state relays, LED, to control devices up
to 20mA.
3 outputs: D1 (10mA, Max Voltage 3,3V)
for LED, solid state relays control.
Max voltage 3,3V
OUT1… OUT4 max current – (-V) 1000 mA.
All outputs can be controlled via short call DIAL or via SMS message. This feature may be used for gate opening
Output alarm parameters may be programmed.
Programmable algorithms for outputs operation:
CTRL/SMS/DIAL, SIREN, BUZER, ARM state, Zones OK, Light Flash, inverting,
pulse mode
A PGM output is a programmable output that toggles to its set up state when a specific event has occurred in the system. Normally,
PGM outputs
can be used to open/ close garage doors, activate lights, heating, watering and much more.
When a PGM output turns ON, the
system triggers any device or relay connected to it.