GTalarm3 User manual V-2022-05-24
26 |
E N
Figure 28 Outputs settings
If you want to edit existing configuration
,
You have to read it (press “Read” in the command line)
Edit settings
Write edited
configuration (press “Write” in the command line)
Outputs can be set as timers.
1.
When output is activated for “Out
Timer” time interval,
2.
Relay contact start changing state
from ON (pulse time ON) to OFF
(Pulse time Off)
3.
This cycle will repeat until output is
deactivated.
Output signal
Pulse time ON
Pulse time OFF
Pulse time ON
Pulse time OFF
Output state
Output ON
Output OFF
Bell:
Output for connection of audible sounder (siren). After the alarm
system actuation a continuous or pulse (fire) signal is generated.
OFF
ON
Alarm
Bell time
Bell
ARM/DISARM:
Output for connection of light indicator of the alarm
system status. When the alarm system is on a continuous signal is
generated.
OFF
ON
ARM/DISARM
Open
Close
Open
ARM
DISARM
Buzzer:
Output for connection of audio indicator. After the alarm system
activated a pulse signal is generated within Exit Delay time, and continuous
signal - within Entry Delay time or when the alarm system is disturbed.
When the alarm system is turned off, operates like keyboard buzzer.
OFF
ON
Open
Command - ARM
Exit Delay
Close
Entry Delay
Command - DISARM
Buzzer
Flash:
Output for connection of light indicator. When the alarm system
is on, a continuous signals generated, and if the alarm system is
disturbed - pulse signal. Signal is terminated by turning off the alarm
system.
OFF
ON
Flash
Open
Command - ARM
Close
Alarm
Open
Remote Control:
Output designed for connection of electrical devices
which will be controlled by SMS message or phone call a) control by SMS
message
SMS
OFF
ON
Remote Control
Pulse
OFF
ON
Remote Control
Level
SMS 1
SMS 2
Remote Control
b) control by phone call
OFF
ON
Remote Control
Pulse
Dial
OFF
ON
Remote Control
Level
Dial 1
Dial 2
System State:
Output for connection of light indicator of the alarm system
status. Within Exit Delay time a pulse signal is generated, and when the
alarm system activated
– continuous. Signal is terminated by turning off the
alarm system.
AC OK:
Output for connection of indicator about control panel supply
from alternating current