GTalarm3 User manual V-2022-05-24
27 |
E N
OFF
ON
System State
Open
Exit Delay
Close
Open
OFF
ON
AC OK
AC OK
AC Lost
AC OK
Ready:
Output for connection of light indicator of input statuses. If all zones
are clear (none violated), a continuous signal is generated.
OFF
ON
Ready
Zone Fault
Zone OK
Battery OK:
Output for connection of indicator about control panel supply
from battery.
OFF
ON
Battery OK
Battery OK
Battery Lost
Battery OK
Alarm indication:
Output for connection of light indicator showing alarm
status of the alarm system. After the alarm system actuation a continuous
signal is generated.
OFF
ON
Alarm Indication
Open
Close
Open
Alarm
Bell Time
Lost Primary Channel:
Output where a continuous signal is generated
when communication with primary channel was lost.
OFF
ON
Lost Primary
Channel
Lost Primary Channel
Restore Primary Channel
Fire Sensor Reset:
Output for reset of fire sensor operation. Its status
changes 5 sec. and returns to the initial one.
OFF
ON
Fire Sensor
Reset
Fire Sensor Reset
5 seconds
Lost Secondary Channel:
Output where a continuous signal is
generated when communication with secondary channel was lost.
OFF
ON
Lost Secondary
Channel
Lost Secondary Channel
Restore Primary Channel
3.5.1
Output PGM wiring. Bell, Relay, Led Wiring
Output switch to ground when activated from the module. Connect the positive side of the device to be activated to the VD+ terminal. Connect the negative
terminal to the selected output.
1.
Connect devices to the selected outputs as shown in the figures below. For sound signaling we recommend to use siren DC 12V up to 1500mA.
It is recommended to connect the siren to the system by using 2 x 0,75 sq. mm double insulation cable. Auxiliary BUZZER is recommended to
be installed inside the premises not far from the entrance. Buzzer operates together with the main siren also when the system starts calculating
the time to leave the premises and the time till alarm response of the security system after entering the premises (see clause 7.1). It is possible
to use buzzer of hit point PB12N23P12Q or similar modified piezoelectric 12V DC, 150mA max Buzzer. Standard AC/DC adapter with the voltage
10V-14V and current >=1A might be used to powering the module
-
+
-
+
I/O
3
C
O
M
O
U
T
4
O
U
T
3
I/O
1
O
U
T
1
O
U
T
2
VD
+
I/O
2
F
la
sh
B
e
ll
B
u
z
z
e
r
GTalarm3
Fig. 1 OUT1-OUT4 Open drain 1000
mA connection
I/O
3
C
O
M
O
U
T
4
O
U
T
3
I/O
1
O
U
T
1
O
U
T
2
VD
+
I/O
2
NO
NC
com
GTalarm3
Fig. 2 Relay connection to OUT1-OUT4, I/O1,
I/O2 20mA
2.2k
2.2k
I/
O
3
C
O
M
O
UT
4
O
U
T3
I/
O
1
IN
4
IN
3
IN
2
D
3
O
UT
1
+5
V
O
UT
2
D
1
D
2
VD
+
C
O
M
IN
1
I/
O
2
GTalarm3
Fig. 3 example of LED connection to output
3.5.2
Access control output with logging
Set output definition to [
Access Gained
] .
This output generates even if access device is granted by user who controls this output.
If user has right to ARM/DISARM system, it always has access to this output.
If ARM/DISARM flag is not set user can access this output only if system is Disarmed (Open).
If access is granted by user, 421 event Access granted is stored into the log. If not Access denied event 422