GTalarm3 User manual V-2022-05-24
4 |
E N
1
General information about the module GTalarm3
1.1
Specifications
Parameters of built-in GSM module:
Quad-band (850/900/1800/1900 MHz)
Optional 3G ,4G LTE bands
Sending of SMS messages
Receiving of calls and dialing
Data download/upload via GPRS network
Outputs (PGM) OUT1-OUT4:
max current
– (-V) 1000 mA;
All outputs can be controlled via short call DIAL
or via SMS message. This feature may be used
for gate opening.
Output alarm parameters may be programmed;
Programmable algorithms for outputs operation:
CTRL/SMS/DIAL, SIREN, BUZER, ARM state,
Zones OK, Light ; Flash, inverting, pulse mode
IN1 - IN4 inputs:
Custom SMS text for input alarm and restore;
Burglary alarm zones. Input type
NC/NO/EOL/EOL+TAMPER 2.2K + 2.2K;
5.1K pull up resistor;
Analog input 0-10V;
Algorithm for zones operation: delay, interior,
instant, 24 hours, silent, fire;
Response time;
Time of repeatable Alarm/Restore;
Commutation of selected output;
Inputs/outputs I/O1, I/O2, I/O3:
Programmable input or output;
Burglary alarm zones. Input type: Input type
NC/NO/EOL/EOL+TAMPER 2.2K + 2.2K;
Analog 0-10V/0-20mA/4-20mA;
Current loop 2-wire smoke detector mode.
Digital inputs/ outputs D1-D3:
Dallas 1-Wire Bus, DS18b20, DS1990A;
Aosong 1-Wire bus Humidity Sensor AM2302
DHT22 AM2305 AM2306 AM2320 AM2321;
Wiegand interface DATA0/ DATA1, RFID reader,
Keyboard;
The total length of the bus from 10 to 100m.
Expansion modules or programmable
input/output:
Expandable inputs up to 32
Expandable outputs up to 32
Module control:
ARM/DISARM of the security system via:
Free SeraNova app (Android, IOS, web)
SMS message 800 users
short call DIAL 800 users
Maxim-Dallas iButton key (iButton DS1990A
–
64 Bit ID)) 800 users.
Wiegand keypad code or RFID keycard or key
fob 800 users
Automatic periodical test:
Test sending in a form of SMS message.
Periodicity for communication control messages
(tests) from 1 to 99 nights and days according to
selected time. Or fixed periodical interval 1-
99999 minutes.
Noce resistant MIC and Speaker (Optional
feature)
Power supply voltage:
DC 8-30 V / 300mA max
Max. Allowed ripple voltage 100mV.
Consumption current:
In standby mode less than 50 mA.
In dialing or SMS/GPRS sending mode
less than 300 mA.
Events Log:
Nonvolatile flash events log 2048 events
4.5V power source output for external
modules:
Voltage 4.5V
Current limit 100mA
Environmental parameters:
Storage temperature range from -40 to +85
o
C / -40 to 185
o
F
Operational temperature range from -30 to
+75
o
C / from -22 to 167
o
F
Max relative humidity under +40
o
C / 104
o
F
95%
Package weight 90g
Module weight: 43g
Overall dimensions of the module:
84x66x18mm
1.2
Used definitions and terms
Term
Description
Alarm Log
Contains information about alarms that are currently active on the system or information about alarms that have been
raised and then resolved on the system. This log can be useful in analyzing problems and trends in the system.
Arming/Disarming
A process of enabling/disabling system's security.
Authorized user
It is a person whose mobile phone’s number is entered in GTalarm3 module. Several authorized users with the same rights
may be entered into the module.
Backup battery
The secondary power source of the system. In case of a main power failure, the backup battery will take over.
Bell squawk
If enabled, the siren/bell indicates the completed system arming and disarming process (except the arming in STAY mode).
After the system is successfully armed, the siren/bell will emit 2 short beeps and 1 long beep after the system is disarmed.
By default, the parameter is disabled.
Bypass/Activate Zone
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed
zone is violated or restored during exit/entry delay, or when then system is armed, it will be ignored. The zone will remain
bypassed until the system is disarmed. Zones can only be bypassed and activated when the system is not armed.
Caller ID
Caller's identification
COM
Negative power supply terminal.
Configuration
Programming of the settings, which will define the operation of the item. For example, user's telephone numbers, set-up of
periodicity for sending SMS message, input names etc.
CMS
Central monitoring station
DIAL
The system makes a call to the number specified.
Diagnostic Tool
When using Configuration tool software, you may monitor system inputs/ outputs, view changes of peripheral devices,
instantly configure necessary options, for example, enabling/disabling PGM outputs, etc.
Entry Delay
The system initiates the entry delay countdown if a Delay type zone is violated. The countdown is indicated by short beeps
emitted by keypad buzzer and by steady beep emitted by system's buzzer. The indication is intended to advise the user
that the system should be disarmed. If the system is disarmed before the entry delay expires, no alarm will be caused.
EOL
(End of line resistor) input type with resistor.