GTalarm3 User manual V-2022-05-24
65 |
E N
Installer code
– 6-digit password used for system configuration, control and request for information. By default, installer code is 000000, which is
highly recommended to change.
User code
– 6-digit password used for system control and request for information. By default, installer code is 000000, which is highly recommended
to change.
The module could be controlled only by these users, whose phone numbers entered in the memory of the module
- Identification:
INST – Install used for module’s configuration.
- Installer’s or user’s password.
- space character
- Command code.
- space character
- First configuration array
- space character
- Second configuration array
- etc.
- Identification:
USER – User used for module’s control.
- Installer’s or user’s password.
- space character
- Command code.
- space character
- First configuration array
- space character
- Second configuration array
- etc.
8
The table of installers commands
SMS commands with
correct INST password
can be send from any phone number. Keep INST password in secret!
SMS configuration is allowed only with Latin characters. Unicode is not allowed.
Table 17 The table of installers commands
INST000000˽001˽N#TEL#SMS#DIAL#System
open close
Programming of users telephone numbers to send SMS and to make a call if the event
occur:
001= programming user‘s tel. numbers for DIAL and send SMS
N = user ID number 1-8
TEL = user‘s telephone number (max 16 digits) without (+) country code, operator‘s code and user‘s
telephone number included. The end symbol #;
SMS = event filter for sms. 1- send event, 0-
don’t send event. Sequence of the events 1.2.3...n For
example: 001000
DIAL = event filter for DIAL. 1-DIAL if the event occur, 0-
don‘t DIAL Sequence of the events
1.2.3...n For example: 101000
#= delimiter
e.g.: INST000000 001 1#37066666666#0001000000#0000011111#
Event filter eiliskumas:
1-reserved
2-system open close
............
...........
10-Input/Zone4 Alarm/Restore
INST000000˽002˽ID
Delete user’s phone number according the
user ID number
. Phone number used for receive
user’s information.
002= command code (deleting user‘s numbers according the user ID number)
ID = user ID number from 1 to 8
INST000000 004 ID#TEL#OUT#OPT#NAME#
To enter user‘s telephone number for remote control via short call
USER NAME-only Latin characters is allowed inside SMS
004= command code (enter user‘s telephone number for remote control via short call)
ID = user ID number 001-800
TEL =
user‘s telephone number (max 16 digits) without (+) comprised of country code, operator‘s
code and user‘s telephone number. the end symbol #;
OUT= output number, that will be controlled, 1-10.
OPT = DIAL function: 0
– disabled 1 – enabled, Sequence from the left to the right
OPT:
1-ARM/DIARM
2-Reserved (GTlarm2 =MIC)
INST000000 005 TEL#
To delete user‘s phone number for remote control, according phone number
005= command code (delete user‘s phone number for remote control, according phone number)
TEL = user‘s phone number (max 16 digits) without (+) comprised of country code, operator‘s code
and user‘s telephone number. User‘s phone number must be the same as in the memory of the
module.
INST000000
˽006˽N
Delete user‘s phone number whose ID number is N.
006= command code (Delete user‘s phone number according user‘s ID number )
N = user‘s ID number from 001 to 800.