GTalarm3 User manual V-2022-05-24
20 |
E N
Figure 16 How to check real time hardware status, real time sensor values. How to receive alarms and where find alarm events list
3.4
Sensors. Security.
3.4.1
Burglar Alarm sensor zones wiring EOL NO NC
In1...In4 Can be used or use it as
security system‘s zones with selectable type: NC/NO/EOL/EOL+TAMPER.
I/O1, I/O2 with selectable type: NC/NO/EOL/EOL+TAMPER. External pool-up resistor 5.1K is required.
It is recommended to use standard motion, fire, and glass breaking sensors. For powering of sensors we recommend to use standard 6-8
wires cable for, designed for installation of security system.
Connect security system‘s sensors to module as is shown in connection diagrams below
Set the required parameters
Write configuration by
pressing „Write“ icon