GTalarm3 User manual V-2022-05-24
31 |
E N
Set Digital I/O D2 to “Wiegand interface DATA0”
Set Digital I/O D3 to “Wiegand interface DATA1”
Press “Write”
Go to Sera2> System Options> General System Options
Set time zone
Set clock synchronization
Press “Write”
Go to Sera2> Users/ Access control window.
Touch RFID keycards, iButton keys to the reader.
Call to the module from your mobile
RFID keycard, iButtons code, phone number will appear in the list.
Go to System Options> General system Options and
Press "Stop programming" or wait until it will stop automatically.
Edit setting in the Users/ Access control window.
Press "Write"
Periodic, recurring at intervals of time access: access schedules, holidays
Holidays should be considered special days of a week. They are similar, but of higher rank than the standard Monday-Sunday.
Temporary access, that self-destructed after a certain time elapses
Suppose you must create a Cleaning Crew schedule. The schedules are to be set up as follows: Monday-Friday 5 p.m.-1 a.m., Saturday and
Sunday 8 a.m.-1 p.m., no holidays. This becomes three separate schedules, as follows.
2 Monday-Friday, 5 p.m.-11:59 p.m. (Remember, the time range cannot cross midnight, so 11:59 p.m. is the limit.)
3 Tuesday-Saturday, 12:00 a.m.-1:00 a.m.
4 Saturday-Sunday, 8:00 a.m.-1:00 p.m.
Note: Holidays should be considered special days of a week. They are similar, but of higher rank than the standard Monday-Sunday. If a day
programmed as a Holiday should occur in the panel, the panel will treat that day as the Holiday type, regardless of the actual day of the week
(Monday-Sunday). During this Holiday, schedules that contain that specific Holiday type will work. The Holiday allows users to further customize
how the panel works. For example, the user can block access to a building on that day, or grant special access during that day. Each Holiday
added is considered a full day, extending from midnight to midnight. The options available when configuring a holiday are Annual, Type, Date
and Year. While Annual is enabled, the date added as a Holiday will be a Holiday every year. This disables the Annual check box and allows a
user to select a specific year, so that only during that date and year will the Holiday selection work.
Figure 46 The example of schedule
DISARM /ARM/SLEEP/STAY
3.6.1
Wiegand Keypad & RFID Card Reader, iButton Probe Wiring
Wiegand keypad specifications:
26bit Wiegand (Default);
8bit key press code
Maxim-Dallas iButton keys (iButton DS1990A
– 64 Bit ID)) can be used to ARM/DISARM security panel or control selected output.
Up to 800 iButton keys can be assigned to the system.
The First iButton key could be learned (recorded) by touching it to the reader. Without the need to send any SMS. The first key is the main
key (MASTER)
The system will notify about successfully recording of the key into memory by shortly beeping twice via buzzer.