GTalarm3 User manual V-2022-05-24
37 |
E N
Figure 45Unlimited number of modules
configuration at the same time
An unlimited number of modules can be configured remotely on the same computer at the
same time. The configuration reading and writing speed does not decrease because the
processes are running in parallel. Many Sera2 programs could be opened and used at the
same time.
If you want to edit existing configuration
,
You have to read it (press “Read” in the command line)
Edit settings
Write edited configuration (press “Write” in the command line)
4.2
General system options programming
The system comes equipped with internal real-time clock (RTC) with battery that keeps
track of the current date and time. Once the system is up and running, the user must set the
correct date and time, otherwise the system will not operate properly. SERA2 software
provides the ability to select the Time Zone and The user may also choose Set module time
from PC, which instantly provides the exact PC time. When the system is connected to the
monitoring station via IP connection the date and time will be automatically synchronized with
the monitoring station. It is possible to select automatically time synchronization with: GSM
Modem, Cloud Server or disable it.
If the module has been connected first time to the power supply, or power supply has been disconnected for a long time, the time of the
module should be set again.
The module can send a trouble report and restrict arming if some of selected troubles [Restrict ARM] exist during close event.
System Options > General system Options
The general system options settings let you control system options, system general
settings, systems timers, let you program iButton keys and reset the module.