Alarm Text:
It is possible to customize alarm text
Restore Text:
It is possible to customize restore text
Zone Hardware Location:
Select the zone hardware input
Wiring Type:
EOL
End of line resistor. Input type with resistor.
NC
The alarm will be send when the circuit between input and ground (-V) will be broken.
NO
The alarm will be send when the input will be connected with ground (-V)
Contact ID code:
The module will automatically generate the reporting event when transmitting to the CMS.
Zone Speed:
Defines how quickly the module responds to an open zone detected on any hardwired input terminal (does not apply to addressable
motion detectors and door contacts).
Event Repeat Timeout:
Insensitive time to recurrent zone events
Max Alarm Count:
When the particular number of zone events set has occurred, the other events of the same zone will not be responded for the time
set in Event Repeat Timeout. After this time expired (or when disarmed), a new count of the number of zone events will be started.
Zone Alarm action:
Determines which output will be activated
Alarm report enabled
: The system will report alarm event and log it to the event buffer
Restore report enabled:
The system will report restore event and log it to the event buffer
Tamper Enabled:
The system will detect a tamper condition with one or more sensors on the system
Bypass Enabled:
The system will allow zones to be Manually Bypassed.
Shutdown if max alarm count
: The system will stop generating alarms once the max alarm count Limit is reached. It resets every time the system will
be armed.
Zone Force ARM:
Only force zones can be bypassed when the module is Force armed. Fire Zones cannot be Force Zones.
Zone definition:
Delay
When armed, provides entry delay when violated. Recommended for door sensors.
Interior
When armed, instant alarm will sound first if the zone is violated; Instant alarm will follow the entry delay if entry delay is active. Recommended
for motion sensor in front of the door.
Instant
When armed, instant alarm when violated.
24 hours
Instant alarm when violated, audible alarm at default not depending from ARM, DISARM modes. Recommended for safes, storehouses,
tampers.
Silent
Always active, not depending from ARM, DISARM modes. The SMS will be send, but the siren will not be activated. Recommended for voltage,
temperature control, AC mains failure control and for alarm of silent panic.
Fire
Instant alarm and communication when violated not depending from ARM, DISARM modes. Siren signal with interruptions will be generated.
Recommended for smoke, fire detectors.
ON/OFF
Interior STAY
Similar to ‘Instant’ except the module will auto bypass the zone if Armed in the Stay mode
Instant STAY
Similar to ‘Instant’ except the module will auto -bypass the zone if Armed in the Stay mode