Out definition:
Access Gained:
If user has right to ARM/DISARM system, it always has access to this output. ? If ARM/DISARM flag is not set user can access this
output only if system is Disarmed (Open).
RH Sensor Trouble:
Output for RH Sensor trouble operation. In this mode output can automatically reset Humidity sensor if trouble occurs.
Fire Sensor:
Output for reset of fire sensor operation. Its status changes 5 sec. and returns to the initial one.
Lost Secondary Chanel:
Output where a continuous signal is generated when communication with secondary channel was lost.
Lost Primary Chanel:
Output where a continuous signal is generated when communication with primary channel was lost.
Alarm Indication:
Output for connection of light indicator showing alarm status of the alarm system. After the alarm system actuation a continuous
signal is generated.
ARM/ DISARM:
Output for connection of light indicator of the alarm system status. When the alarm system is on a continuous signal is generated.
Battery OK:
Output for connection of indicator about control panel supply from battery.
AC OK:
Output for connection of indicator about control panel supply from alternating current.
Automation & Access Control:
Remote control by call mode is enabled. Output designed for connection of electrical devices which will be controlled by
SMS message or phone call
Ready:
Output for connection of light indicator of input statuses. If all zones are clear (none violated), a continuous signal is generated.
System State:
Output for connection of light indicator of the alarm system status. Within Exit Delay time a pulse signal is generated, and when the alarm
system activated
– continuous. Signal is terminated by turning off the alarm system.
Flash:
Output for connection of light indicator. When the alarm system is on, a continuous signals generated, and if the alarm system is disturbed - pulse
signal. Signal is terminated by turning off the alarm system.
Buzzer:
Output for buzzer connection. After the alarm system activated a pulse signal is generated within Exit Delay time, and continuous signal - within
Entry Delay time or when the alarm system is disturbed. When the alarm system is turned off, operates like keyboard buzzer.
Bell:
Output for connection of audible sounder (siren). After the alarm system actuation a continuous or pulse (fire) signal is generated.
Disable:
Output disabled
Mode:
Steady:
Steady ON/OFF mode
Timer:
Output ON pulse mode
Out Timer:
Pulse time duration can be from 1 to 999999 sec.
Invert:
Inversion is activated
Pulsating:
Pulsating mode is activated. Then output is activated. It will pulsate according pulse ON/OFF time.
Pulsating ON Time:
Pulsating mode pulse ON duration.
Pulsating OFF Time:
Pulsating mode pulse OFF duration.
4.7
Users & Access Control programming details.