GTalarm3 User manual      V-2022-05-24 

 

 

54  | 

E N

   

SIM ICCID 

ICCID (Integrated Circuit Card Identifier)

 - A SIM card contains its unique serial number (ICCID). 

ICCIDs are stored in the SIM cards and are also printed on the SIM card. 

SIM Card 

If note READY is visible, it means that SIM card is fully functioning. Otherwise, check whether PIN 
code request is off or replace SIM card. 

Signal level 

Signal strength of GSM communication 

Registration 

State of GSM modem registration to GSM network. 

SMS Service Centre 
Address 

SMS center number. This number should be checked if it is correct. If this number is incorrect. SMS 
messaging may be impossible. This number may be changed after inserting SIM card into any mobile 
phone. 

System Voltage 

Power supply voltage. Nearby number is value of ADC voltage. When multiplying this number by the 
coefficient Fig. 32, voltage value (V) will be achieved. 

10 

System Voltage 

System voltage OK/Trouble 

11 

RTC Clock 

Real time clock OK/Trouble 

12 

Module Real Time Clock 

Indicates the time of the module RTC 

13 

Set RTC Clock 

By pressing this button real time clock of the module will be set. 

14-17    

Inputs In1…In4 

In1…In4 is the indicated input ADC and voltage value V. 

18-19 

I/O1…I/O2 

I/O1…I/O2 is the indicated voltage ADC value and current ADC value mA. 

20-22 

D1…D3 (I/O) 

Check box nearby the digital inputs D1…D3 (I/O) means that the input has ‘0’ or ‘1’ state. 

23 

BUS (I/O) 

Check box nearby the zone expansion module BUS (I/O) means that the input has ‘0’ or ‘1’ state. 

24-27 

Out1…Out4 On/Off 

Checked box nearby the appropriate output 

Out1…Out4  

means that this output currently has ‘0’ or ‘1’ 

state. The output could be activated by pressing On/Off button 

28-29 

I/O1…I/O2 On/Off 

Checked box nearby the appropriate input/output 

I/O1…I/O2 

means that this input/output currently has 

‘0’ or ‘1’ state. The output could be activated by pressing On/Off button 

30-32 

D1…D3 (I/O) On/Off 

Checked check box nearby the digital outputs 

D1…D3 (I/O)

 

means that the output currently has ‘0’ or 

‘1’ state. 

33 

BUS (I/O) On/Off 

Checked check box 

BUS (I/O)

 

means that the output currently has ‘0’ or ‘1’ state. 

 

4.12  RT Testing & Monitoring Security Alarm Panel/ Access  

 

 

 

RT Testing & Monitoring > Security Alarm Panel/ Access 

The Security Alarm Panel/ Access window let you see real time zones states: is zone 
alarmed, bypassed, forced etc. This window it let you change system state: disarm, arm, 
sleep, and stay. This window let you look to access control area also. 

 
 

2

3

4

5

6

7

8

13

14

15

16

9

10

11

12

17

18

19

1

 

Figure 51 the example of RT Testing & Monitoring > Security Alarm Panel/ Access window

 

 

If the checkbox is checked and the color is red the trouble is indicating. If color is green, trouble is not indicated. The text nearby indicates the trouble. 

 

Table 10 Explanation of every field in "Security Alarm Panel/ Access" window 

Zone1…Zone32 

Zone number 

Alarm 

If checked and the color is red the zone is alarmed 

Alarm Shutdown 

If checked and the color is red alarm shutdown for the zone is activated. Allowable number of the 
same alarm events is reached and the same events will not be reported. 

Bypassed 

If checked and the color is red, the zone is bypassed. 

Forced 

If checked and the color is red, the zone is forced 

Tamper/Fault 

If checked and the color is red, the zone is tampered. 

Summary of Contents for GTalarm3

Page 1: ...GTalarm3 Installation Programming Manual Security monitoring and automation system This manual includes steps to install set up and use your system...

Page 2: ...d even growing tents Automation Remote control and monitoring various devices by GSM GPRS SMS DIAL WEB Internet FEATURES Report system events to a monitoring station Internet Protocol Event Reporting...

Page 3: ...er iButton Probe Wiring 31 3 6 2 Enter iButton RFID Phone numbers to the memory of the module 32 3 7 How to set clock synchronization 33 5 Programming 35 5 1 SERA2 Uploading Downloading Software 35 5...

Page 4: ...orage temperature range from 40 to 85 o C 40 to 185 o F Operational temperature range from 30 to 75 o C from 22 to 167 o F Max relative humidity under 40 o C 104 o F 95 Package weight 90g Module weigh...

Page 5: ...or Is that it weakly pulls the voltage of the wire it is connected to towards V or whatever voltage represents a logic high PGM output A PGM output is a programmable output that toggles to its set up...

Page 6: ...1 pcs User s guide in PDF Program SERA2 1 4 General view of the module 1 Micro SIM card holder of Push Push type 2 GSM antenna connector 3 RESET button 4 Mini USB programming connector 5 REG yellow se...

Page 7: ...ects internally to COM Max available current 1000mA Max available voltage 30V 8 9 10 I O1 I O3 30 Programmable functions The zone for security system NC NO EOL EOL Tamper 1 Output 20mA Analog current...

Page 8: ...rd via cloud app also in SERA remote default 123456 Installer code for SMS control and configuration 000000 INST000000 090 PSW 090 command code Change of installer s code PSW New Installer s password...

Page 9: ...t 2 QUICK START First steps to prepare GTalarm3 and SERA2 software QUICK START https youtu be NR35lbFdi8A Preparation procedure of the module GTalarm3 Connect the GSM antenna to the antenna connector...

Page 10: ...ply the security system from stabilized power supply source 10 15 V and not less than 1 5A It is necessary to calculate max current of power supply The current of the alarm system is the current used...

Page 11: ...GTalarm3 User manual V 2022 05 24 11 E N Figure 6AC loss in Burglar alarm window...

Page 12: ...y to follow all electrical safety requirements 3 2 Inputs The module GTalarm3 has 7 burglary zones Can be expanded up to 32 4 analog inputs In1 In4 0 30V for analog sensors connection Or can be used a...

Page 13: ...It would therefore seem that any particular device is not guaranteed to meet these specifications For all the other devices the numbers above are the maximum tolerances and most also offer better typ...

Page 14: ...onitoring 9 It is possible to receive alarm SMS to the mobile phone GSM Communication SMS Dial reporting 10 Real time sensor values and states RT Testing Monitoring Sensors Automation 11 Write configu...

Page 15: ...Set the required parameters 4 Sensors could be calibrated 5 Press Write Figure 11Analog sensors settings Any automation voltage analog sensors 0 10V can be connected to IN1 IN4 has internal pull up re...

Page 16: ...temperature monitoring systems inside buildings equipment or machinery and process monitoring and control systems Applications Uses Consumer Products Industrial Systems Thermally Sensitive Systems The...

Page 17: ...istor in series in the data line of each sensor before connecting to the network The total length of the bus from 10 to 100m Depending of cable quality sensors number on bus and environment noise Ther...

Page 18: ...ime hardware status RT Testing Monitoring Hardware Press Start Monitoring 8 The list of alarm events with time and date stamp RT Testing Monitoring Event Monitoring 9 It is possible to receive alarm S...

Page 19: ...step How to check real time hardware status real time sensor values How to receive alarms and where find alarm events list 7 Real time hardware status RT Testing Monitoring Hardware Press Start Monito...

Page 20: ...zones with selectable type NC NO EOL EOL TAMPER I O1 I O2 with selectable type NC NO EOL EOL TAMPER External pool up resistor 5 1K is required It is recommended to use standard motion fire and glass...

Page 21: ...OUT4 OUT3 I O1 IN4 IN3 IN2 D3 OUT1 5V OUT2 D1 D2 VD COM IN1 I O2 GTalarm3 Figure 19 NO With EOL COM NC TAMPER NO COM NC ALARM RELAY OUTPUT sensor EOL cable EOL zone input com 2 2k 2 2k tamper switch N...

Page 22: ...or I O2 you have to connect external 5 1K resistor between I O and VD as is shown in attached diagram I O1 I O2 do not have internal pull up resistors So if you want to connect NO NC sensors to I O1...

Page 23: ...ery level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics 5 In the living area s of a guest suite 6 In the living area s o...

Page 24: ...ng is supervised by the control panel The parameters of the zone should be defined as a Fire Zone I O1 and I O2 can be defined as a 2 wire smoke detector input if a line short occurs or the smoke dete...

Page 25: ...ration algorithms Automation CTRL Siren Buzzer ARM state Zones OK Light Flash inverting pulse mode 3 open drain 20mA outputs I O1 20mA I O3 20mA These outputs can be used for solid state relays LED to...

Page 26: ...pulse signal is generated within Exit Delay time and continuous signal within Entry Delay time or when the alarm system is disturbed When the alarm system is turned off operates like keyboard buzzer O...

Page 27: ...ve terminal to the selected output 1 Connect devices to the selected outputs as shown in the figures below For sound signaling we recommend to use siren DC 12V up to 1500mA It is recommended to connec...

Page 28: ...mode In order to control big power alternating current equipment it is comfortable to use solid state relays Standard AC DC adapter with the voltage 10V 14V and current 1A might be used to powering th...

Page 29: ...text to the system s phone number USER 123456 030 ST 030 command code Change security system s mode ARM DISARM STAY SLEEP ST Security system mode 0 DISARM 1 ARM 2 STAY 3 SLEEP Arm Disarm by keypad To...

Page 30: ...r will call from this number Preferred input may be assigned to each user s number Thus different users are able to control different objects ARM DISARM If this check box is checked a user will be abl...

Page 31: ...s of a week They are similar but of higher rank than the standard Monday Sunday If a day programmed as a Holiday should occur in the panel the panel will treat that day as the Holiday type regardless...

Page 32: ...to the memory of the module First steps Connect iButtons or RFID reader to the module Insert SIM card Screw GSM antenna Connect power supply Connect the module to the computer Configurations methods...

Page 33: ...iButton RFID Caller ID Learning Mode Stopped INST000000 063 S INST Install Configuration of the parameters 000000 Installer s password Space character 063 command code iButton keys learning deleting m...

Page 34: ...ire Bus must be set Refer to Users Access Control programming details 3 7 How to set clock synchronization If you received SMS messages with wrong date time you need to set clock synchronization corre...

Page 35: ...iguration press Write in the command line Figure 40 SERA2 Command line 4 Programming In order to configure and control the system by SMS text message send the text command to the GTalarm3 phone number...

Page 36: ...ings may be saved at PC It enables to save time when next time the same configuration will be used it will not be necessary again to set the same parameters If you want to save that is already recorde...

Page 37: ...rrect date and time otherwise the system will not operate properly SERA2 software provides the ability to select the Time Zone and The user may also choose Set module time from PC which instantly prov...

Page 38: ...armed disarmed or that an Entry or Exit Delay was triggered Auto reARM Arm the module if there is no activity in the area after the system disarming Stop iButton RFID programming To finish entering iB...

Page 39: ...and voltage is dropped below allowed value Event Delay System low voltage trouble event report delay Audible alarm when disarmed alarm as per zone when armed When disarmed Generates Audible Alarm The...

Page 40: ...can be expanded GTalarm3 zones can be expanded with expansion module up to 32 Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone If a bypassed...

Page 41: ...t be disabled The tamper circuit is a single closed loop such that a break in the loop at any point will cause a tamper alarm regardless of the system status armed or disarmed During the tamper alarm...

Page 42: ...t a tamper condition with one or more sensors on the system Bypass Enabled The system will allow zones to be Manually Bypassed Shutdown if max alarm count The system will stop generating alarms once t...

Page 43: ...ection of electrical devices which will be controlled by SMS message or phone call Ready Output for connection of light indicator of input statuses If all zones are clear none violated a continuous si...

Page 44: ...nal code iButton Code iButton key DS1990A 64 Bit ID code Might be entered manually or automatically registered after the module enters keys association mode In order to delete the code it is necessary...

Page 45: ...ng Crew schedule The schedules are to be set up as follows Monday Friday 5 p m 1 a m Saturday and Sunday 8 a m 1 p m no holidays This becomes three separate schedules as follows 2 Monday Friday 5 p m...

Page 46: ...d in one of four modes DISARM ARM SLEEP STAY By default it is allowed to arm the system while the following system faults are present Low battery Battery dead or missing Battery failed Date time not s...

Page 47: ...smits the defined report code and generates an audible alarm When armed Follows Zone Alarm Type The module follows the zone s alarm type Trouble always Generates Trouble Only when armed or disarmed Tr...

Page 48: ...rough 8 for monitoring purpose receive alarm phone calls via GSM connection and SMS text messages from the system When the system is armed or disarmed by free of charge phone call or SMS text message...

Page 49: ...the next listed user phone number assigned to the same zone The user can be unavailable due to the following reasons Mobile phone was switched off mobile phone was out of GSM signal coverage or provi...

Page 50: ...xt SMS Text Text which will be visible in SMS message is entered Alarm SMS message text of Alarm report Restore SMS message text of Restore report Open SMS message text of Open report Close SMS messag...

Page 51: ...during the remote connection session process the data messages will be queued up and transmitted to the monitoring station after the remote connection session is over while during the remote firmware...

Page 52: ...station CMS is disable switch to backup CMS after n attempts 9 Return To Primary After n min Return To Primary After n min 10 Encryption AES128 The Encryption option validates the encryption of messa...

Page 53: ...Numerical Report Options 1 1 RT Testing Monitoring Hardware RT Testing Monitoring Hardware The Hardware monitoring window let you see real time input output actions and GSM information Thus it would b...

Page 54: ...appropriate output Out1 Out4 means that this output currently has 0 or 1 state The output could be activated by pressing On Off button 28 29 I O1 I O2 On Off Checked box nearby the appropriate input...

Page 55: ...implest application viewing data to more sophisticated uses such as sending a text message when an alarm occurs or transmitting a data log file over the internet from a remote location to a central of...

Page 56: ...red Read icon 5 The connected sensors will appear in the list Figure 54 the example of Automation Sensors Automation Sensors Analog Inputs window How to set sensor s parameters Double click on the sel...

Page 57: ...Unit Sensor Unit Text 6 Max Value Alarm Event SMS Max Val SMS Maximum allowable temperature value which will be reported 7 Max Value To Activate Output Max Val OUT Maximum allowable temperature value...

Page 58: ...least Temperature X ADC Y 12 Contact ID Report Code Max CID Max and Min Contact ID report codes Report codes are the Ademco CID SIA DC09 format The module can automatically program a set of default r...

Page 59: ...tion by MIN and MAX boundaries System faults Configuration via USB User phone number that initiated the remote configuration Communication with monitoring station status Figure 58 the example of the E...

Page 60: ...to GSM Communication window Sera Cloud Service tab Set Sera Cloud Service to Default parameters 5 Write the configuration into the module by pressing Write icon Figure 59 How to find GSM Communicatio...

Page 61: ...ected notification SERA2 software can remember all IMEI that was entered in the past If needed to clean the list UID IMEI press Clear History Figure 61 Command line Settings Clear history 4 17 Testing...

Page 62: ...green the sensor is active 4 High Val Alarm If checked and the color is red the high value alarm is generated 5 Low Val Alarm If checked and the color is red the low value alarm is generated 4 17 2 Re...

Page 63: ...No Updates System Options System Info The System Info window let you take a look to the main hardware boot loader firmware serial no IMEI ICCID information 1 2 3 4 5 Figure 65 How to find required Sy...

Page 64: ...s the problem with sensor s connection to the module If the problem still exist please read save and send the configuration to the seller Describe what and how is connected to zone 001 and send this i...

Page 65: ...SMS event filter for sms 1 send event 0 don t send event Sequence of the events 1 2 3 n For example 001000 DIAL event filter for DIAL 1 DIAL if the event occur 0 don t DIAL Sequence of the events 1 2...

Page 66: ...anel 12 Lost secondary chanel 13 Fire sensor14 RH Sensor trouble 15 Access Gained INST000000 020 N Invert output state 020 command code outputs inversion N output number from 1 to 10 INST000000 021 N...

Page 67: ...1 31 HH hours 0 23 mm minutes 0 59 INST000000 094 TEL SMS SMS from the module forwarding to the other phone number SMS from the module forwarding to the other phone number 094 command code SMS from t...

Page 68: ...99 Time interval in seconds for the output activation USER123456 030 ST Change security system s mode ARM DISARM STAY SLEEP 030 command code Change security system s mode ARM DISARM STAY SLEEP ST Secu...

Page 69: ...OT install the module near water e g bathtub wash bowl kitchen laundry sink wet basement or near a swimming pool Do NOT install the module and its accessories in areas where there is a risk of explosi...

Page 70: ...on purporting to act on its behalf to modify or to change this warranty nor to assume for it any other warranty or liability concerning this product WARNING UAB Topkodas recommends that the entire sys...

Page 71: ...any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by sensing changes in temperature However their effectiveness can be reduced when the...

Reviews: