Figure 7.
Distribution of refractory elements in the furnace firebox for combustion of pellets
In a closed heating system the installation of a certified safety valve opening pressure of 2.5
bars is required, and installation of expansion vessel. Locking element must not be installed
between the safety valve, expansion vessel and boiler.
Water temperature in boiler may not fall below 55
0
C not to cause condansate.
In the event of severe winter weather and low temperature, and when the boiler is not used it is
necessary to drain waiter from the system or fill it with antifreeze liquid.