It is only necessary to connect flue gas fan, which is flanged for multi cyclone, and the
chimney through the square chimney pipe. Multi cyclone is connected by chimney pipe, of round
cross section to the boiler, and then by the flue gas fan to chimney. Chimney pipes should be
insulated with mineral wool against the fire.
The connections between multi cyclone and boiler, multi cyclone and chimney are done
by clamp with thermo resistant pads. Flue gas pipe between the flue gas fan and chimney must
be angled out more than 10º
Figure 12
Multi cyclone
– chimney connection
Before installation of the chimney, it is necessary to make the basis of the chimney with anchor
bolt M36. Anchor bolts are delivered by the producer, as well as the sketch of the basis,