Do not close free air supply to the boiler.
WARNING
-
The furnace must be placed on a stable, flat surface. Setup
and installation of the furnace must be conducted by
a
professional.
-
Water supply connections must be provided in the furnace
room, plus a connection for possible drainage and electrical
connection with
mandatory grounding.
-
The furnace room should have natural ventilation that provides
fresh air.
-
The floor and inside the boiler room must be made of fireproof
materials.
It is desirable that the room is not damp, in order to avoid the corrosion of metal parts, with the
goal of extending life.
Softened water is recommended for filling the boiler in the system.
Circulation pump is put into operation only when the heating system is filled with water. What
must be taken into account is that the system is vented.
When connecting the furnace and chimney, the flue pipe should be placed horizontally or
vertically. All connections must be well sealed.
The chimney must be sized according to the diagram in Figure No. 5.
Insufficient airflow, ie. when geometric features of chimney as indicated in Figure 5 herein have
not been met, there is a real risk of transmission of the flame from the firebox into the pellet
feeder tube, and then in the pellets reservoire which can cause a fire.
Summary of Contents for BTA1000
Page 70: ...BTA User Guide Topling Prnjavor Page 70...
Page 71: ...BTA User Guide Topling Prnjavor Page 71...
Page 72: ...BTA User Guide Topling Prnjavor Page 72...
Page 73: ...BTA User Guide Topling Prnjavor Page 73...
Page 74: ...BTA User Guide Topling Prnjavor Page 74...
Page 75: ...BTA User Guide Topling Prnjavor Page 75...
Page 76: ...BTA User Guide Topling Prnjavor Page 76...
Page 77: ...BTA User Guide Topling Prnjavor Page 77...
Page 78: ...BTA User Guide Topling Prnjavor Page 78...
Page 79: ...BTA User Guide Topling Prnjavor Page 79...