Figure 22.
Cleaning of tubes
Figure 23.
Cleaning kit
If in the course of exploitation you hear noisy operation of flue gas ventilation, the highest
probability is that the impeller is dirty. Then at the first stop of the system, the bolts on the flange
of the flue gases fan should be unfastened on the top of multicyclone, and then the cleaning of
fan circuit and the fan body is carried out.
.
Figure 24.
Cleaning of tubes
Important: Cleaning shall be performed only when the system is not in operation. After
termination of the operation, wait for 15 minutes and then start cleaning.