SYSTEM CHECK-UP
Before performing the start-up operation check that the automation is correctly installed, the door is closed and that the
DIP switches, the plugs and the spring are correctly positioned as described on page 5.
If the installation includes the DS2S digital selector, follow the instructions for operation and start-up included with the
selector.
GIVE POWER TO THE AUTOMATION BY POSITIONING THE POWER SWITCH IN "ON"
The electronic board in its native state
shows on the display the following
flashing symbol:
CHECK THE CONFIGURATION OF THE MAIN PARAMETERS
If your installation differs from those parameters, follow the programming instructions on page 21
START THE SELF LEARNING PROCESS
•
Clear people or things off of the safety sensors detection areas. There must be no obstacles in the door movement
area during the whole procedure.
• Start the self-learning procedure by pressing both keys <ENTER> and <DOWN> on the automation for 5 seconds.
The display shows the word “RESET” blinking.
•
The automation acknowledges the presence of the safety sensors, controls that the door is closed and starts a
cycle by opening 70°.
•
At this point, move the door manually to maximum opening position desired.
!!! PERFORM ONLY THE OPENING MOVEMENT OF THE DOOR: IN THE EVENT OF WRONG
POSITIONING,REPEAT THE PROCEDURE FROM THE BEGINNING !!!
Press the <ENTER> button on the board to confirm the maximum
opening point.
After 20 seconds, the door closes and goes back to normal operation.
If the self-learning procedure has been completed successfully, the
detected sensors are shown on the display (as in the example in the side)
to allow the installer to verify the correct acquisition of the sensors.
If an error occurs, check the error map on page 20.
In Full Energy it is essential that at least the two main safety sensors are installed, the lack of even one of the sensors
causes an error. The safety sensors are monitored and therefore must respond when the test signal is enabled. In
this way the electronics recognizes the sensors that respond to the test signal as present. If non-monitored sensors are
used, before performing the self-learning procedure, the installer must change the parameter 105 (for programming
see pages 21) of the sensor logics to disable the test.
For programming remote controls (up to 8):
1.Press and hold the <DOWN> key for 5 seconds, the display shows the word “RADIO” blinking on the 7-segment display.
2.If you are using the 4-channel Topp TS1S remote control, press the second button (closed function). To confirm that the remote control
has been memorized, the blinking word “RADIO” will no longer be displayed.
For removing: memorized remote controls
1.Press and hold the <DOWN> key for 5 seconds, the display shows the word “RADIO” blinking on the 7-segment display.
2.Press and hold the “DOWN” key for a further 5 seconds, all connected remote controls are cleared. To confirm that all programmed remo
-
te controls have been removed, the blinking word “RADIO” will no longer be displayed.
A
b
C
d
E
2
3
1
2
1
FIRST STARTUP - SELF LEARNING
S200
Radar logics: N.O. with the inside safety sensor in closure which commands door opening
VALUE
Door weight 75 Kg
Door width 800 mm
Architrave depth 0 mm
Safety sensors logic: N.C. with active high test
DESCRIPTION
-parameter 101
-parameter 102
-parameter 103
-parameter 104
-parameter 105
PARAMETER
Safety sensor in closing
-
Safety sensor in opening
-
Supplementary
Safety sensor
in opening
-
Supplementary
Safety sensor
in closing
-
Summary of Contents for S200
Page 20: ...20 instructions for installation LIST OF ERROR MESSAGES AND NOTICES S200 ...
Page 26: ...26 instructions for installation PRE WIRED ELECTRIC CONNECTIONS S200 ...
Page 30: ...30 EC DECLARATION OF CONFORMITY instructions for installation S200 ...