25
instructions for installation
CONFIGURATION OF AUTOMATION PARAMETERS
S200
ref.
display
parameter description
val.
*default*
value description
129
FINAL STROKE
Serves to regulate the closing velocity and
facilitate the fastening of the electric lock.
*0*
1
2
3
4
5
6
7
8
9
Increasing the value increases the force.
130
ELECTRIC LOCK STATUS CON
-
TROL MODE
Perm its control of lock s tatus . Connection of input
12 to GND is checked.
*0*
1
2
Absent
electric lock in UNLOCK-STATUS if connect to GND
electric lock in LOCK-STATUS if connect to GND
131
FORCED OPENING
Force on opening toward clos ing direction for releas
e of electric lock. Certain locks m ay need to pus h
toward clos ure before unlocking in order to open the
lock.
*0*
1
2
3
4
5
6
7
8
9
Increasing the value increases the force.
132
ELECTRIC LOCK OPERATING
MODE
Indicates the operating m odes that lock the electric
lock or the electroblock.
*0*
1
2
3
Disabled
Block with s elector on “closed”
Block with s elector on “closed” or “exit only” or “entry only”
Block with s elector on “clos ed” or “exit only” or “entry
only” or “autom atic”
133
ELECTRIC LOCK LOGIC
Indicates who electronic lock is controlled. Values
from 5 to 8 s erve for locks that can work with 24V
power panel with duty cycle at 50%
*0*
1
2
3
4
5
6
7
8
No lock
Lock if powered
Lock if not powered
Impulsive (s electing the parameter “=” with a value different of 0)
Bistable: One impulse opens and another closes
Lock of powered at duty 50%
Lock if not powered at duty 50%
Impulsive at duty 50%
Bistable: One impulse opens and another closes at duty 50%
134
I
NTERLOCKING MODE
*0*
1
2
3
4
Disabled
Interlock with independent internal radars and electriclocks closed.
Interlock with independent internal radars and electriclocks opened.
Interlock with common radar and electriclocks closed.
Interlock with common radar and electriclocks opened.
135
DOUBLE WING FUNCTION AND
DISABLED RESTROOM
Serves to program certain particular functions
necessary for double wing doors and the disabled
restroom.
*0*
1
2
3
4
5
6
7
8
9
Disabled
Coordinated double wing - Master
Coordinated double wing - Slave
DS2S reserved
DS2S reserved
DS2S reserved
DS2S reserved
DS2S reserved
DS2S reserved
Disable restroom function with single wing
136
MASTER – SLAVE DELAY ANGLE
iOn double-wing door, it indicates the angle of delay
of starting to open or close the master-slave wings.
0
1
2
3
*4*
5
6
7
8
9
Adjustable from 0 to the maximum offset degree