background image

ELECTRICAL PARAMETERS

TPSM6U-240W

TPSM6U-245W

Maximum Power Voltage - Vmp (V)

29.70

30.00

Maximum Power Current - Imp (A)

8.09

8.17

Open Circuit Voltage - Voc (V)

36.80

37.00

Short Circuit Current - Isc (A)

8.58

8.69

Maximum Power - Pmax (W)

240

245

Maximum Series Fuse (A)

16

Max-System Voltage (VDC)

1000

Dimensions (mm)

16

40

*99

2

*40

Weight (kg)

18.6

5

Series Mono-crystalline Solar Modules

ELECTRICAL PARAMETERS

TPSM6U-285W

TPSM6U-290W

TPSM6U-295W

TPSM6U-300W

Maximum Power Voltage - Vmp (V)

35.40

35.60

35.80                       32 36.20

Maximum Power Current - Imp (A)

8.05                    8

8.15

8.24

8.30

Open Circuit Voltage - Voc (V)

44.60

44.70

45.00

45.20

Short Circuit Current - Isc (A)

8.57

8.61

8.68

88.71

Maximum Power - Pmax (W)

285

290

295

300

Maximum Series Fuse (A)

16

Max-System Voltage (VDC)

1000

Dimensions (mm)

1956*99

2

*50

Weight (kg)

23

M6U(72) Series Mono -crystalline Solar Modules

ELECTRICAL PARAMETERS

TPSP6U-235W

TPSP6U-240W

TPSP6U-245W

Maximum Power Voltage - Vmp (V)

29.70

29.80

30.10

Maximum Power Current - Imp (A)

7.92

8.06

8.14

Open Circuit Voltage - Voc (V)

36.80

36.90

37.10

Short Circuit Current - Isc (A)

8.52

8.62

8.69

Maximum Power - Pmax (W)

235

240

245

Maximum Series Fuse (A)

16

Max-System Voltage (VDC)

1000

Dimensions (mm)

16

40

*99

2

*40

Weight (kg)

18.6

Table 7

12

TPSM6U-250W

30.30

8.25

37.30

8.

76

2

50

TPSM6U-255W

30.50

8.

36

37.50

8.

82

2

5

5

TPSP6U-250W

30.30

8.26

37.20

8.80

250

M6U

P6U

6

Summary of Contents for TPSM5U

Page 1: ......

Page 2: ...TALLATION Operation Conditions Site Selection Tilt Angle Mechanical Drawing of Module Mounting ELECTRICAL INSTALLATION Electrical Specifications Module Wiring and Connector Grounding Junction Box with...

Page 3: ...ormed by qualified licensed professionals Before installing a solar photovoltaic system installers should familiarize themselves with its mechanical and electrical requirements Keep this guide in a sa...

Page 4: ...le Do not disassemble the modules or remove any part of the module Do not damage or scratch surfaces or back side of the module Do not drill holes in the frame This may compromise the frame strength a...

Page 5: ...glass surface and the frame may be hot there is a risk of burns and electric shock Avoid exposing cables to direct sunlight in order to prevent their degradation Keep children well away from the syste...

Page 6: ...r obstructions which could cast shadows on the modules especially during the winter months when the arc of the sun is lowest over the horizon Shading causes loss of output even though the factory fitt...

Page 7: ...will be satisfactory during the rest of the year Topray Solar recommends a minimum installation angle of 10 degrees because this enables dust to be washed off by rain or dew for greater light intensit...

Page 8: ...ng methods Modules can be mounted by using moun ng holes at the module frame with corrosion proof screws Modules can be mounted by using suitable module clamps on the long side of the module frame Mod...

Page 9: ...dified under any circumstances When choosing this type of clamp mounting method please be sure to use at least four clamps on each module two clamps should be attached on each long side of the module...

Page 10: ...rystalline 1956 992 50 500 TPSP6U 60 Poly crystalline 1640 992 50 400 TPSP6U 72 Poly crystalline 1956 992 50 500 Table 2 Module Mechanical Dimensions When Clamp on the Long Side of the Frame C Clampin...

Page 11: ...n each module Two clamps should be attached on each short side of the module Depending on the local wind and snow loads one clamp should be attached on each long side of the module if needed The mount...

Page 12: ...6 992 50 200 Table 3 Module Mechanical Dimensions When Clamp on the Short Side of the Frame required wiring damage and to allow cooling air to circulate around the back of the module This also allows...

Page 13: ...When designing the PV system please always take into conside the n of the voltage under di erent temperatures please check the temperature coe cients of the modules the Voc of the modules will be ris...

Page 14: ...tage Voc V 44 60 44 70 45 00 45 20 Short Circuit Current Isc A 8 57 8 61 8 68 88 71 Maximum Power Pmax W 285 290 295 300 Maximum Series Fuse A 16 Max System Voltage VDC 1000 Dimensions mm 1956 992 50...

Page 15: ...strings Please refer to the applicable regional and local codes for addi fuse requirements When necessary please install blocking diodes to protect modules or system been damaged by reverse current Do...

Page 16: ...l shading of an individual module can cause a reverse voltage across the shaded module Current is then forced go through the shaded area by the other modules When a bypass diode is wired in parallel w...

Page 17: ...rst be shut down Improper maintenance can cause lethal electric shock and or burns OWNERSHIP This manual is the proprietary property of Topray Solar Co Ltd No part of this manual may be reproduced or...

Page 18: ...Co Ltd Address Tel 86 755 86612630 ASIA 49 089 3741 2030 EUROPE Fax 86 755 86612620 ASIA 49 089 3741 2028 EUROPE Email support topraysolar com Topray Solar Industrial Area Hi Tech Park West Guangming...

Reviews: