Figure 2-7 Operational sensitivity adjustment
Step 6: Set voltage protection, as shown in Figure 2-8.
1. Use a multimeter to measure the actual voltage value.
2. If the actual voltage value does not match the main measurement value, enter the
actual voltage value in the box and click the
“
Calibration
”
button to calibrate.
3. Set voltage protection.
If you do not need the flight controller to perform the low voltage protection
action, you can turn it off. At this time, the flight controller will only flash the alarm
when the voltage is low. The yellow light flashes for one level of protection, and the
red light flashes for two levels of protection.
If you start the low-voltage protection action, you can further set the "first-class
protection" to "landing" or "return." If the setting is "return flight", automatic return
trip is performed when the primary protection is triggered. If the setting is "landing,"
an in-place landing is performed when the primary protection triggers. When the
secondary protection triggers, the in-place landing will be performed automatically
When the remote controller is out of control after the low-pressure
protection is turned on: if "primary protection" is set to be "return to base",
the aircraft will automatically return; if it is set to be "landing", it will
perform to land in place.