6
1 - Technical Catalogue
TO320 T - EN - Ed. 04.09
TECHNICAL DATA
3.
Type
Ambient
Temp.
(°C)
Process
Temp.
(°C)
Differential
pressure
(bar)
Wt. of VDC
with counter-
weight (kg)
Wt. of mo-
tor-operated
VDC (kg)
Wt. of
pneumatic
VDC (kg)
Maximum
pc. size
(Ø mm)
200
-10/ +50
Max.500
0.05
115
140
120
68
250
-10/ +50
Max.500
0.05
160
190
170
75
315
-10/ +50
Max.500
0.05
205
240
220
90
400
-10/ +50
Max.500
0.05
380
420
400
110
500
-10/ +50
Max.500
0.05
490
570
550
140
Type Hopper capacity
(dm3)
Filling
coefficient
Theoretical throughput*
(dm3/h)
200
4
0.5
1200
250
7
0.5
2100
315
14
0.5
4500
400
31
0.5
9300
500
59
0.5
17700
* Calculated for 600 activation cycles/hour
Volume conveyed at each cycle according to the filling coefficient
0
10
20
30
40
50
60
0,2
0
,4
0,6
0
,8
1
1
,2
VD
C200
VD
C250
VD
C315
VD
C400
VD
C500
VOLUME CONVEYED (dm
3
)
FILLING COEFFICIENT
Summary of Contents for VDC 200
Page 1: ...VDC Double dump valve EN TO320 EN Ed 04 09 ...
Page 7: ...TECHNICAL CATALOGUE TO320 T EN Ed 04 09 1 VDC Double dump valve EN ...
Page 24: ......
Page 25: ...VDC Double dump valve EN OPERATION AND MAINTENANCE TO320 M EN Ed 04 09 2 ...
Page 66: ......
Page 67: ...SPARE PARTS CATALOGUE VDC Double dump valve EN TO320 R EN Ed 04 09 3 ...
Page 76: ...10 3 Spare Parts Catalogue TO320 R EN Ed 04 09 Plate 2 Counterweight 2 1 2 4 2 3 5 ...