24
2 - Operation and maintenance
TO320 M - EN - Ed. 04.09
Motor-operated VDC
12.5
Levers assembly order
12.5.1
1. Fit lever (1) on the shaft of the VDC ensuring
that the key present on the shaft is centred in
relation to the lever;
2. Fit grub screw (10) on the lever;
3. Insert screw (9) and washer (8) in lever (1);
4. Insert spacer (2), a washer (6), a spacer (5)
and bearing (3) on screw (9);
NOTE: repeat these operations for the other le
-
ver.
5.Insert spring (7) on bearing (3);
6.Insert spacer (5) and washer (6);
7. Screw nut (4).
NOTE:
repeat these operations for the other lever.
Drive unit support assembly order
12.5.2
1. Position the stud bolts (19) on the
valve body and fit screws (16) (RH
screw in drawing) together with
washers (17-18);
2. Position the drive unit support
plate (20) on stud bolts (19) and fit
screws (16) (LH screw in drawing)
together with washers (17-18).
4
6
5
3
2
1
8
9
10
7
1
7
1
8
1
9
20
1
8
1
7
16
16