2 - Operation and maintenance
35
TO320 M - EN - Ed. 04.09
Maintenance
12.8
Before carrying out any operation on the machine, make sure it is in safety condition!
Daily maintenance
12.8.1
-At the end of the day's work, empty the valve;
-Check daily for signs of overheating, vibrations and abnormal noise
Weekly maintenance
12.8.2
-Check the gear motor oil level;
-Remove the rear cover checking for the presence of material inside the body;
In case of normal use:
check for the presence of lubricant in the bearings once a
week;
In case of heavy-duty service:
check for the presence of lubricant in the bearings twice a
week;
Monthly maintenance
12.8.3
-Check the state of the bearings and replace those that are worn;
-Check the state of the bearing and levers for movements (if present);
-Check the state of the spring;
-Check the state of the cylinders (if present);
Yearly maintenance
12.8.4
-Remove the valve from the plant and the closure of the flaps;
-Check the state of the flaps and hoppers;
Note: for ATEX reduction gears refer to the producer's Manuals.
Summary of Contents for VDC 200
Page 1: ...VDC Double dump valve EN TO320 EN Ed 04 09 ...
Page 7: ...TECHNICAL CATALOGUE TO320 T EN Ed 04 09 1 VDC Double dump valve EN ...
Page 24: ......
Page 25: ...VDC Double dump valve EN OPERATION AND MAINTENANCE TO320 M EN Ed 04 09 2 ...
Page 66: ......
Page 67: ...SPARE PARTS CATALOGUE VDC Double dump valve EN TO320 R EN Ed 04 09 3 ...
Page 76: ...10 3 Spare Parts Catalogue TO320 R EN Ed 04 09 Plate 2 Counterweight 2 1 2 4 2 3 5 ...