26 - EN
T100 R
Menu 5 Various settings
Menu
item
Entry
Selection
51
Function of external control devices
0
Off (default setting)
1
Dead man open / dead man close
2
Pulse open / dead man close
3
Pulse open / pulse close
4
Pulse 1/2 door opening / pulse close
5
AR operation, automatic closing
6
AR operation, 1/2 door opening
7
Open/close operation
8
Open / close pulse as NO contact
52
001-256 Entry of control address
53
Door control module
0
off (default setting)
1, 2, 3, 4 DC module
5
RadioSafe module, wireless closing edge (op-
tional)
6, 7
reserved
55
Door setting for smoke and heat extraction
system position
- -
Exit menu
Menu 6 Radio
Menu
item
Entry
Selection
60
Programming the start button on the hand-held
transmitter
61
Programming the 1/2 opening button on the hand-
held transmitter
62
Programming the light button on the hand-held
transmitter
63
Deleting radio codes
Press for 5 s
64
Deleting radio codes
0
off (default setting)
1
Pulsed operation open/stop/close
2
Automatic closing AR
3
Open/close operation
- -
Exit menu
Menu 7 drive settings
Menu
item
Entry
Selection
70
Soft start with reduced torque
0
Off
1 - 13
Time 60 ms - 300 ms (in steps of 20 ms)
71
0 - 40
Deceleration path before reaching upper end
position in cm (10 cm = default setting)
72
0 - 20
Reduced torque (16 = default setting)
- -
Exit menu
Menu 9 Service menu
menu
item
Entry
Selection
90
Selection of the door maintenance cycle
0
No service interval (default setting)
1
10000 cycles
2
20000 cycles
3
30000 cycles
4
40000 cycles
5
50000 cycles
6
60000 cycles
7
80000 cycles
8
100000 cycles
9
120000 cycles
10
150000 cycles
11
200000 cycles
12
250000 cycles
91
Cycle counter output
door cycles
96
Operating hours counter output
– hours
97
Error memory output
hours – error code
98
Software version output
– serial number – creation
date
99
Reset to default setting
Press for 5 s
- -
Exit menu
Diagram for door run and recommended settings
71
70
72
Speed
Time
Menu 7 Recommended settings
Menu item
SI 4,5.90
SI 8.120
SI 20.90
SI 35.60
70
Soft start acceleration time
5
0
8
7
71
Soft stop
20
25
20
20
72
Reduced torque
15
0
10
10
Summary of Contents for T100 R
Page 107: ......