16
DETERGENT SOLUTION TANK
The solution tank is provided with an inspection
opening. This permits to clean the exit point of
the detergent solution.
Be sure that the cap is well tightened after the
cleaning.
The capacity of the detergent solution tank is indi-
cated in the technical data.
Open the screw plug (1) placed in the rear left
part of the machine and fill the detergent solution
tank with clean water at a maximum tempera-
ture of 50°C (122°F). Add the liquid detergent in
the percentage and conditions foreseen by the
manufacturer. To avoid excessive foam presence,
which could cause problems to the suction motor,
use the minimum percentage of detergent. Screw
down the plug to close the tank.
Always use low foam detergent. To avoid foam
presence, before starting working operation, in-
troduce into the recovery tank a minimum quan-
tity of anti-foam product.
Never use pure acid.
STARTING OF THE MACHINE
1. Turn the key (8) clockwise.
2. Check the battery type and the charge level on
the display (1).
3. Press the base motor switch (5).
4. Press the suction motor switch (6).
5. Press the solenoid valve switch (4).
6. Acting upon the base lifting pedal (13) lower
the base.
7. Acting upon the solution valve lever (11) open
and adjust the solution detergent flow.
The water starts to flow automatically acting upon
the levers drive control (9). On the instrument
board the indicator of the solenoid valve switch
(4) will turn on. Releasing these levers, the flow
will stop.
https://harrissupplyind.com - To Order Parts Call 608-268-8080