background image

7

IMPORTANT SAFETY 

INSTRUCTIONS

SAVE THESE INSTRUCTIONS

•  

DO NOT

 use to clean up any burning or lighted 

materials such as cigarettes, matches, ashes, or 
other combustible objects.

•  Only use the machine on firm, level surfaces. 

DO NOT

 use the machine on gradient or slope of 

more that 2%.

•  

CAUTION

 –This machine is for dry, indoor use 

only and should not be used or stored outdoors 
or in wet conditions. 
Protect from rain.

•  Take care when using this machine near the top 

of stairs to avoid loss of balance.

•  

DO NOT

 cover the machine when in use.

•  

DO NOT

 run the machine dry as this 

could damage the floor surface and/or the 
machine itself.

•  

DO NOT

 leave the machine running unattended.

•  Keep hair, loose clothing, hands, feet, and all 

other parts of the body away from openings and 
moving parts. Do not put hands under base as 
rotating parts can cause injury. 

•  

DO NOT

 put any object into openings. 

DO NOT

 

use with any opening blocked. Keep free of dust, 
debris and anything that may reduce airflow.

•  

DO NOT

 use volatile or combustible solvents 

(e.g., diesel, petrol, PA, trichloromethane) nor 
any corrosive, toxic, or highly irritant substance 
to wash floors, even if diluted. In the event of 
accidental contact with any such substances 
(e.g., due to spills) follow the decontamination 
procedures in force at the user site. If in any 
doubt about the condition of the machine, 
contact Tornado or the dealer/agent who 
supplied the machine.

•  

DO NOT

 leave the machine unattended when 

plugged in. Unplug from outlet when not in use 
and before changing brushes or attempting any 
maintenance or adjustment.

•  

DO NOT

 fill the machine with water hotter than 

135°F (57°C).

•  When used on escalators, ensure the machine 

is positioned at the bottom of the escalator with 
the escalator moving towards the operator.

•  

DO NOT

 pull or carry by cord, use cord as a 

handle, close a door on cord, or pull cord around 
sharp edges on corners.

•  

DO NOT

 run machine over cord. Keep cord away 

from heated surfaces.

•  

DO NOT

 unplug by pulling on cord. To unplug, 

grasp the plug, not the cord. Do not handle plug 
or machine with wet hands. Turn off all controls 
before unplugging.

•  Connect only to a properly grounded outlet. See 

grounding instructions.

•  Use care to keep electrical supply cable from 

contacting moving parts such as floor brushes.

•  Make sure voltage and frequency at the wall 

receptacle correspond with that indicated on 
nameplate before plugging in machine.

•  The machine must be kept clean and in good 

condition with regular inspections of the power 
cord and plug for signs of any damage. If any 
parts are damaged, they shall only be replaced 
by an approved part by the manufacturer, its 
service agent or a similar qualified person in 
order to avoid a hazard.

•  Only replace the power cord with original 

OEM equipment.

Summary of Contents for TE310-G15-U

Page 1: ...1 Model No TE310 G15 U SURGE 500 UPRIGHT EXTRACTOR OPERATIONS AND MAINTENANCE MANUAL FOR COMMERCIAL USE ONLY...

Page 2: ...anty 4 Grounding Instructions 5 Important Safety Instructions 6 Cleaning Agents 8 Technical Specifications 9 Operating Instructions Controls 10 Operation 11 Warnings 12 Transport and Storage 13 Mainte...

Page 3: ...or damage Unpack all internal parts ensure no hidden damage is found Each unit is tested and thoroughly inspected prior to shipping If damage is discovered immediately notify the transportation compan...

Page 4: ...components will void all warranty claims Warning Labels Prior to operating the unit read and understand completely this owner s manual paying special attention to warning labels These labels indicate...

Page 5: ...properly installed and grounded in accordance with all local codes and ordinances Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualifie...

Page 6: ...st be performed by a qualified service agent DO NOT modify the machine from its original design Operators must be fully trained in the use of the machine in accordance with these instructions and be a...

Page 7: ...the user site If in any doubt about the condition of the machine contact Tornado or the dealer agent who supplied the machine DO NOT leave the machine unattended when plugged in Unplug from outlet wh...

Page 8: ...able footwear to avoid slipping Wear suitable clothing to keep dry Do not smoke when using the machine Do not use excessively foaming or highly corrosive cleaning solutions If operating on a flooded f...

Page 9: ...Vacuum Motor Airwatt 625 Watts Pump 50 500 p s i 3 4 34 bar CFM CMM 133 3 8 Waterlift 125 in 0 31 bar Heater Single Element Solution Tank Capacity 15 Gallon 57 Liters Recovery Tank Capacity 15 Gallon...

Page 10: ...NTROLS Fig 1 Fig 2 PUMP VACUUM SOLUTION QUICK DISCONNECT Fig 3 PUMP HEATER VACUUM VACUUM PRESSURE SETTINGS PRESSURE REGULATOR SOLUTION QUICK DISCONNECT HEATER ON PUMP BREAKER DUAL CIRCUIT 1 2 6 3 5 4...

Page 11: ...erating 6 Turn the pump switch 1 Fig 1 to the ON position 7 Turn the vacuum switch 3 Fig 1 to the ON position to begin cleaning 4 Fig 1 is a blank cover 8 With the solution line attached to the want a...

Page 12: ...micals with abrasive additives voids the warranty DO NOTt use any replacement parts except those specified on the parts list Performance of the machine could be affected if substitutions are made DO N...

Page 13: ...transporting the machine ensure that all components tanks and removable parts are securely fastened and that the power cord and plug are not trailing DO NOT lift or transport the machine while it con...

Page 14: ...ment clean both inside and out 2 Lubricate brass quick disconnects with a quality lubricant such as WD 40 3 Flush solution systems after use with clear clean water A white vinegar solution may also be...

Page 15: ...and any other foreign material from screen 2 Remove and clean Leaking or stuck solution valve 1 Foreign material in valve 2 Loose brass hex nut 3 Valve or seals worn 1 Remove brass hex plug clean val...

Page 16: ...um motor 2 Float activated 3 Recovery tank full 1 Replace 2 Clean float 3 Empty recovery tank Premature activation of the recovery tank float 1 Dirty or clogged float 1 Clean float Foam dirty solution...

Page 17: ...17 NOTES...

Page 18: ...310 G15 U 04 2022 Tornado Industries LLC 3101 Wichita Court Ft Worth TX 76140 1755 Phone 800 VACUUMS Fax 1 817 551 0719 WWW TORNADOVAC COM Serial Number Purchase Date Dealer Phone Number Record of Pur...