background image

4

Your new Tornado unit is a 
high quality, precision-made 
product. All parts used in the 
manufacturing of this unit have 
passed rigid quality control 
standards prior to assembly. 
Please safeguard the original 
receipt / invoice. If you 
experience any problems with 
your unit during the warranty 
period, the original receipt 
/ invoice will act as proof of 
purchase. Contact Tornado for 
any warranty inquiries.

GENERAL RULES OF SAFETY

The rules below have to be 
followed carefully in order to 
avoid injury to the operator 
and damage to the machine.
− Read the labels carefully 
on the machine. Do not cover 
them for any reason and 
replace them immediately if 
damaged.
− ATTENTION: The machine 
must be used exclusively by 
authorized staff that have been 
instructed on its correct and 
proper use.
− ATTENTION: Do not use the 
machine on areas having a 
higher gradient than the one 
stated on the number plate.
− ATTENTION: The machine 
is not to be used by persons, 
children included, with 
reduced physical, sensorial 
or mental capabilities, or 
with lack of experience or 
knowledge, unless they 
could benefit, through the 
intermediation of a responsible 
person for their safety, by a 
supervision or instructions 
concerning to its use.
− During the operation of the 
machine, pay attention to 
other people and especially to 
the children.

− Children shall not play with 
the machine.
− Children cannot carry out 
cleaning and maintenance of 
the machine.

TRANSFER

− Do not strike shelvings or 
scaffoldings where there is 
danger of falling objects.
− Leaving the machine in 
parking position, remove the 
key and apply the parking 
brake.
− Do not use the machine as a 
means of transport.
− Adapt the working speed 
to the conditions: particularly, 
slow down before narrow 
curves have to be faced.

STORAGE AND DISPOSAL

− Storage temperature: 
between 32°F and 131°F
(0°C and +55°C).
− Perfect operating 
temperature: between 32°F 
and 104°F (0°C and +40°C).
− The humidity should not 
exceed 95%.
− Provide for the scrapping of 
the material of normal wear 
following strictly the respective 
rules.
When your machine has to 
stop activity, provide for the 
appropriate waste disposal 
of its materials, especially 
oils, batteries and electronic 
components, and considering 
that the machine itself 
has been, where possible, 
constructed using recyclable 
materials.

CORRECT USE

− Do not use the machine 
on surfaces covered with 
inflammable liquids or dusts 
(for example hydrocarbons, 
ashes or soot).

− The machine has to carry out 
simultaneously the operations 
of washing and drying. 
Different operations must be 
carried out in restricted areas 
prohibited to non-authorized 
personnel and the operator 
has to wear suitable shoes.
− Signal the areas of moist 
floors with suitable signs.
− Do not mix different 
detergents, avoiding harmful 
odours.
− Avoid brush operation 
when the machine is standing 
still in order to prevent floor 
damages.
− Before lifting the recovery 
tank, make sure that it is 
empty.

MAINTENANCE

− If the machine does not work 
properly, check by conducting 
simple maintenance 
procedures. Otherwise, ask 
for technical advice from an 
authorized service center.
− For any cleaning and/or 
maintenance operation take 
off the power supply from the 
machine.
− Where parts are required, 
ask for ORIGINAL spare parts 
from the distributor and/or 
from an authorized dealer.
− Use only ORIGINAL brushes 
indicated in the paragraph 
“RECOMMENDED BRUSHES”.

− Restore all electrical 
connections after any 
maintenance operation.

− In case of fire, use a powder 
based fire-extinguisher. Do not 
use water.
− Do not use the machine in 
explosive atmosphere.

Summary of Contents for TS120-S53-U

Page 1: ...TH TX 76140 PHONE 800 VACUUMS FAX 817 551 0719 WWW TORNADOVAC COM Operations Maintenance Manual For Commercial Use Only Form No T OM680LT 05 21 Tornado Industries LLC All rights reserved AUTOMATIC SCR...

Page 2: ...2 NOTES For warranty information go to www tornadovac com Within 30 days to activate the warranty go to https tornadovac com services warranty registration form aspx...

Page 3: ...ction of the batteries to the machine 12 Starting of the machine 12 Overflow device 13 Emptying detergent solution 13 Forward movement 13 Stop 13 STOP OF THE MACHINE AFTER CLEANING OPERATION 14 DAILY...

Page 4: ...the conditions particularly slow down before narrow curves have to be faced STORAGE AND DISPOSAL Storage temperature between 32 F and 131 F 0 C and 55 C Perfect operating temperature between 32 F and...

Page 5: ...tection level IP X3 Tension V 24 Do not take off the protections which require the use of tools for their removal Do not wash the machine with direct water jets or with high water pressure nor with co...

Page 6: ...ymbol denoting the open book Indicates that the operator has to read the manual before the use of the machine Symbol that indicates the obligation of wearing safety glasses Symbol denoting the open bo...

Page 7: ...QUEEGEE HOSE 9 BATTERIES 10 INLET OPENING SQUEEGEE HOSE 11 SUCTION COVER 12 SOLUTION TANK 13 WHEELS 14 SQUEEGEE ASSEMBLY 15 CASTOR WHEELS INSTRUMENT BOARD AND CONTROLS 1 IGNITION SWITCH 2 BATTERIES CH...

Page 8: ...quipment due to weight and coupling system The batteries must be in accordance with CEI 21 5 Norms The connection of the batteries cables has to be carried out by specialized staff because the inversi...

Page 9: ...and proceed as follows 1 Insert the plug into the mains socket 2 Proceed with the recharging keeping the recovery tank lifted see under paragraph ACCESS TO THE BATTERY COMPARTMENT in BEFORE USE Never...

Page 10: ...eight Note The wheels of the squeegee support must be adjusted through the registers 5 at the same height so that the squeegee works parallel to the floor ADJUSTMENT OF THE SQUEEGEE INCLINATION In cas...

Page 11: ...nsert the brush into its plate seat underneath the brush base turning it until the three metal buttons are properly seated in their slots rotate quickly the brush to push the button towards the coupli...

Page 12: ...or 1 to the machine connector 2 placed in the rear part of the machine STARTING OF THE MACHINE 1 Press the switch ignition 1 0 1 2 Check the charge level on the display or on the signal lamp battery c...

Page 13: ...o appropriate containers according to the standard norms for the liquid disposal EMPTYING DETERGENT SOLUTION To empty the detergent solution remained in the solution tank 1 Bring the machine to an app...

Page 14: ...ANK CLEANING 1 Hold the drain hose placed in the front part of the machine 2 Take off the drain plug acting upon its lever and empty the recovery tank into appropriate containers see under OVERFLOW DE...

Page 15: ...e and sliding the stud bolts 1 in their slots up to their release 3 Clean with care the internal part of the squeegee inlet eliminating dirt residue 4 Clean with care the squeegee rubbers 5 Reassemble...

Page 16: ...Unscrew the solution tank cap 1 3 Unscrew the solution filter 2 being careful not to lose or to damage the gasket 4 Rinse with a water jet the solution tank 5 Rinse the solution tank filter placed in...

Page 17: ...s and follow the assembling instructions at SPLASH GUARD ASSEMBLY paragraph With the brush assembled the splash guard must slightly touch the floor TROUBLESHOOTING GUIDE The checking of all the other...

Page 18: ...rized technical assistance 2 The brush has worn bristles Check the brush wear condition and eventually replace it the brush has to be replaced when the bristles have reached a height of about 15mm To...

Page 19: ...mark the floor or ruin the polishing BRISTLES THICKNESS Thicker bristles are more rigid and must be used on smooth floor or floor with small joints On irregular floors with deep joints or relieves it...

Page 20: ...20...