Electrical
System
Reelmaster 5500-D
Page 5 - 17
Electrical System (Rev. C)
Glow and Start Relays
The start relay is attached to the radiator shield, and the
glow relay mounts to the hydraulic oil filter bracket. Both
relays are located below the seat (Fig. 12).
Note: The start relay may be manufactured by one of
three different manufacturers. Verify manufacturer
name and part number before performing the resistance
check on the relay coil.
Note: Prior to taking small resistance readings with a
digital multi meter, short the test leads together. The me-
ter will display a small resistance value (usually 0.5
ohms or less). This resistance is due to the internal re-
sistance of the meter and test leads. Subtract this value
from from the measured value of the component you are
testing.
1. Verify coil resistance between terminals 86 and 85
with a multimeter (ohms setting).
A. For the glow relay (Bosch #0 332 002 150), re-
sistance should be from 41 to 51 ohms (Fig. 13).
B. For the start relay (Bosch #0 332 204 182), re-
sistance should be from 80 to 90 ohms (Fig. 14).
2. Ground terminal 86 and apply +12 VDC to terminal
85. The relay should pick up making the sound of a
sharp click.
A. For the glow relay resistance between terminals
30 and 87 should be 1 ohm or less.
B. For the start relay, resistance between terminals
30 and 87A should read as an open circuit.
3. 12 VDC from terminal 85. The relay should
drop out making the sound of a sharp click.
A. For the glow relay resistance between terminals
30 and 87 should read as an open circuit.
B. For the start relay, resistance between terminals
30 and 87A should be 1 ohm or less.
4. Disconnect voltage and leads from all terminals.
1. Start
relay
2. Glow
relay
3. Radiator
shield
Figure 12
2
1
3
Figure 13
86
87
85
30
30
87
85
86
Glow Relay
Start Relay
Figure 14
86
87
85
30
87A
85
86
30
87
87A
Summary of Contents for 00075SL
Page 2: ...Reelmaster 5500 D ...
Page 4: ...Reelmaster 5500 D ...
Page 6: ...Reelmaster 5500 D ...
Page 64: ...Reelmaster 5500 D Hydraulic System Rev C Page 4 26 This page is intentionally blank ...
Page 170: ...Reelmaster 5500 D Page 5 40 Electrical System Rev C ...
Page 192: ...Reelmaster 5500 D Differential Axle Page 6 22 ...
Page 254: ...Reelmaster 5500 D Groomer Rev C Page 8 1 14 ...
Page 278: ...Reelmaster 5500 D Page 10 2 Electrical Diagrams Rev C ...
Page 284: ...Rev C Page 10 8 Harness Drawing Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Page 285: ...Rev C Page 10 9 Harness Diagram Reelmaster 5500 D Serial Number 210000401 to 210999999 ...
Page 286: ...Rev C Page 10 10 Harness Drawing Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Page 287: ...Rev C Page 10 11 Harness Diagram Reelmaster 5500 D Serial Number 220000001 to 220999999 ...
Page 288: ...Rev C Page 10 12 Harness Drawing Reelmaster 5500 D Serial Number Above 230000000 ...
Page 289: ...Rev C Page 10 13 Harness Diagram Reelmaster 5500 D Serial Number Above 230000000 ...
Page 290: ...Reelmaster 5500 D ...