Traction Circuit (Closed Loop) Component Failure (continued)
IMPORTANT
When operating the traction system with the high pressure filter
installed, make sure that flow is always directed through the filter
(e.g. do not press the traction pedal in the reverse direction if the
filter is placed for forward direction flow). If flow is reversed, debris
from the filter will re−enter the traction circuit.
The alternative to using the Toro high flow hydraulic filter kit after a traction circuit
component failure would be to disassemble, drain and thoroughly clean all
components, hydraulic tubes and hydraulic hoses in the traction circuit. If any
debris remains in the traction circuit and the machine is operated, the debris can
cause additional circuit component failure.
Hydraulic System: General Information