Figure 9
1.
Li+ diagnostic wire
harness P04 connector
2.
Battery wire harness P04
connector
Uninstalling the Li+ Diagnostic
Wire Harness
Perform the following 4 short procedures to uninstall the
Li+ diagnostic wire harness:
Raise the Battery Pack and Platform
1.
Raise the back of the battery platform until the locking
holes in the front of the battery platform and frame
align (
Figure 10
1.
Battery pack and platform
3.
Locking holes
2.
Pivot bolts and nuts
2.
Insert a 6-mm (1/4-inch) steel rod (e.g., screwdriver)
through the locking holes to hold the battery platform
in the raised position (
Disconnect the Li+ Diagnostic Harness
1.
On the bottom of the battery pack, disconnect the Li+
diagnostic wire harness P01 connector by rotating the
locking collar counter-clockwise approximately half of
a turn (
).
g030574
3
2
1
Figure 11
1.
Battery harness P01
connector
3.
Battery-pack connector
2.
Locking collar
2.
Disconnect the Li+ diagnostic wire harness P34
connector from the main wire harness P34 connector
(
).
10