4.
Measure the resistance between main contactor terminals J03 and J04. Normal resistance is 180 to 195 ohms.
Figure 91
Main Harness Main Contactor Terminal Identification
1.
J02 and J05
3.
J01
2.
J03
4.
J04
Pass
The test found no short condition in the main contactor and the coil tested good. Go to
the Equipment to Service (page 19)
and follow the steps listed.
Fail
The test identified a short in the main contactor and/or wrong resistance in the coil. Replace the
contactor. Go to
Returning the Equipment to Service (page 19)
and follow the steps listed.
Electrical Diagram
Figure 92
The main contactor connects the battery pack and the electric motor. The TEC-2401 circuitry monitors the voltage at several
locations to ensure that the contactor is working properly and the voltage is correct at all components for operation.
112