InfoCenter Diagnostics Screen Icons
The InfoCenter diagnostics screen displays the current status of various machine electrical components and power supply
voltages. Use the diagnostics screen to check the operation of the machine switches and controls when possible.
To find additional information on navigating the InfoCenter menu items, refer to the
eFlex Service Manual
Chapter 4, Electrical
System, InfoCenter Diagnostics Screen section.
Diagnostics icon
Description
Display state
Possible states
Notes
The key is in
the O
N
position
ON
ON
OFF is not displayed, as the power is not
available.
The key is
on the S
TART
position
OFF
ON/OFF
Momentary key switch position
Parking brake
latch
ON
ON/OFF
ON = open
OFF = grounded
EZ-Turn
OFF
ON/OFF
Traction
FWD
FWD/OFF
Reel enable
ON
ON/OFF
Throttle
0V to 5V
Throttle rotated fully backward = 0 to 1
Volts. Throttle rotated fully forward = 4 to
5 Volts
Target speed
(rpm)
rpm (numeric
value)
The demanded target rpm
1
Motor speed
(rpm)
rpm (numeric
value)
The actual motor rpm
1
12 Vdc supply
Volts (numeric
value)
Voltage reading for the 12 Vdc power
supply. A good reading is 10.5 to 13.8
Vdc.
5 Vdc supply
Volts (numeric
value)
Voltage reading for the 5 Vdc power
supply. A good reading is 4.91 to 5.09
volts.
CAN bus
Normal
Indicates the status of the machine
communication bus
1: Examining the target speed (rpm) versus the actual speed (rpm) aids in finding possible excessive machine loads internally
(adjustment, wear, or damage) and or externally applied loads (debris or terrain).