Step 5.6:
Test the TEC-2401 and associated wiring.
1.
Connect the main wire harness P01 connector to the TEC-2401 (
).
2.
Use a multimeter to measure the resistance between the main wire harness P37 connector, pins A and B (
). The reading should be 148 k to 181 k ohms (148,000 to 181,000).
Pass
The resistance reading was good. Go to Step 5.7.
Fail
If the resistance reading was not good, go to Step 5.6.1.
Step 5.6.1:
Test the TEC-2401 wiring.
1.
Disconnect the main wire harness P01 connector from the TEC-2401 (
2.
Check for continuity between the following pairs of locations:
Location
Harness
Connector
Pin
Connector Graphic
1
Main
P37
A
B
C
A
2
Main
P01
11
1
12
7
6
1
Main
P37
B
B
C
A
2
Main
P01
12
1
12
7
6
Figure 66
Main Harness P01 and P02 Connector Pin Identification
1.
Main wire harness P01 connector
3.
TEC-2401 controller
2.
Main wire harness P02 connector
67