Figure 82
Battery Adapter Harness P04 and P26 Connector Pin Identification
Battery Adapter Harness P04 Connector
Pin Identification
Description
Wire Color
POS
42 to 64 Vdc Power
Red (R)
P1
Not used (GT150 cavity plug)
Not used
P2
Not used (GT150 cavity plug)
Not used
S1
Not used (GT150 cavity plug)
Not used
S2
Not used (GT150 cavity plug)
Not used
NEG
Ground
Black (BK)
3.
Use dry compressed air (maximum 20 psi/137 kPa) to remove any debris or moisture from the battery wire harness P04
connector (
) and the battery adapter wire harness T-handle P04 connector that plugs into it.
WARNING
Compressed air is extremely forceful and can dislodge dirt and dust particles that can enter your
eyes or be inhaled.
•
Wear safety glasses to protect your eyes from airborne debris.
•
Wear a dust mask to avoid inhaling dirt and dust particles.
Note:
Ensure the cavity plugs in the battery adapter harness P04 connector (
) are not removed during the
compressed air cleaning process.
4.
Connect the battery pack. Refer to
Connecting the Battery Pack (page 17)
.
Pass
The fault did not repeat. Go to
Returning the Equipment to Service (page 19)
and follow the
steps listed.
Fail
The fault repeated. Go to step 5.
Step 5:
Remove 2 access covers to aid troubleshooting.
Performing these steps provides access to connectors on the wire harnesses.
1.
Remove the console cover. Refer to
Console Cover (page 19)
.
2.
Remove the power center cover. Refer to
Power Center Cover (page 20)
.
92