Greensmaster 3300/3400
Page 6 -- 32
Electrical System
Fuse Block (Greensmaster 3400 with Serial Number Below 312000000)
The fuse block on Greensmaster 3400 machines is at-
tached to the frame under the operator seat (Fig. 33).
In addition to the fuses in the fuse block, a 50 amp
maxi--fuse is included in the wire harness. This fuse pro-
tects the engine cooling fan circuit and resides in a fuse
holder under the right side cover next to operator seat.
Fuse Identification and Function
Use Figure 34 to identify each individual fuse and its cor-
rect amperage. Fuses for Greensmaster 3400 ma-
chines Greensmaster 3400 machines with a serial
number below 312000000 have the following function:
Right Fuse 1 (2 Amp):
Protects TEC logic and igni-
tion switch power supply circuits.
Right Fuse 2 (7.5 Amp):
Protects TEC output power
supply for start relay, engine run solenoid, fuel pump,
glow relay, glow plug indicator light and console diag-
nostic light.
Right Fuse 3 (7.5 Amp):
Protects TEC output power
supply for fan relay, cutting reels engage solenoid, lift
enable solenoid (S1) and lift/lower solenoid (S2).
Right Fuse 4 (7.5 Amp):
Protects TEC output power
supply for lift solenoids S3 (front cutting units), S4
(center cutting unit) and over temperature indicator
light.
Left Fuse 1 (10 Amp):
Protects power supply for
hour meter, low engine oil pressure indicator light, al-
ternator and proximity switches (parking brake, neu-
tral and mow).
Left Fuse 2 (15 Amp):
Protects power supply for
start relay and solenoid.
Left Fuse 3 (15 Amp):
Protects power supply for op-
tional Turf Defender
TM
Leak Detector system and
optional lights.
Left Fuse 4:
Not used.
Fuse Testing
Make sure that ignition switch is OFF and key is re-
moved from switch. Remove fuses from the fuse block
for testing. Fuse should have continuity between fuse
terminals.
1. Seat base (raised)
2. Fuse block
Figure 33
1
2
Figure 34
RUN
STARTER
LIGHTS
LIFT REEL
REEL ENGAGE
START/RUN
DIAG. LIGHT
GLOW
LEAK DETECTOR
LIFT/LOWER
FAN
OVER TEMP
7.5A
7.5A
7.5A
2A
15A
10A
15A
TEC LOGIC
POWER
RIGHT
4
3
2
1
LEFT
15A
15A
10A
7.5A
7.5A
7.5A
2A
Summary of Contents for 04510 Greensmaster 3300 TriFlex
Page 2: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 4: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 6: ...Greensmaster 3300 3400 This page is intentionally blank ...
Page 24: ...Greensmaster 3300 Page 3 6 Gasoline Engine This page is intentionally blank ...
Page 38: ...Greensmaster 3400 Page 4 4 Diesel Engine This page is intentionally blank ...
Page 54: ...Greensmaster 3300 3400 Hydraulic System Page 5 2 This page is intentionally blank ...
Page 170: ...Greensmaster 3300 3400 Hydraulic System Page 5 118 This page is intentionally blank ...
Page 172: ...Greensmaster 3300 3400 Page 6 2 Electrical System This page is intentionally blank ...
Page 230: ...Greensmaster 3300 3400 Page 6 60 Electrical System This page is intentionally blank ...
Page 303: ...Greensmaster 3300 3400 Groomer Page 9 13 This page is intentionally blank Groomer ...
Page 318: ...Greensmaster 3300 3400 Page 10 2 Foldout Drawings This page is intentionally blank ...
Page 332: ...Page 10 16 This page is intentionally blank ...