Start Process
When the key switch is turned to the START position, the machine electrical
system goes through a wake-up process. The contactor in the battery pack
should click as it is energized followed by the main contactor being energized
(audible click). Both the TEC and electric motor controller will be initialized. Once
the InfoCenter display comes on-line, the key switch can be turned to the RUN
position and the machine will be ready for operation.
Run Process
The traction bail lever controls the traction speed potentiometer. This traction
speed potentiometer is used as an input by the TEC which communicates to
the electric motor to engage. The motor rotation speed and traction speed
is determined by the throttle potentiometer setting that is adjusted by the
operator. Actual motor speed is monitored by the TEC and motor controller so
that as traction load changes (e.g., moving up or down an incline) the motor
can compensate as necessary.
Greensmaster
®
e1021/e1026
Page 5–5
Electrical System: Electrical System Operation