220G Series Brass Valve 

Installation and Operating Instructions

220G Series Brass Valve 

Installation and Operating Instructions

Introduction

Specifications

The 220G Series valve offers two electrical activation types:  

AC powered and DC powered.
For satellite systems, the 24 VAC Spike Guard solenoid provides 20,000 volt 

lightning protection to minimize down time and service costs. Moreover, it 

draws less than half the wattage of traditional solenoids for a lower long-term 

cost of ownership. 
For GDC 2-wire systems, a DC-latching solenoid reduces the system wire load 

to lower initial system cost. It is activated by a momentary pulse “on” and “off”, 

meaning there is no continuous power draw, providing a lower long-term cost 

of ownership.
The 220G brass valve adjusts easily with the micro-adjust dial and indicator to 

provided constant downstream pressure between 5-100 psi (,34-6,9 bar).

Note

: The 220G valve should be installed below grade in a valve box or vault 

(see opposite page) to provide service access and vandal resistance. The valve 

installation site should be readily accessible by grounds maintenance personnel 

and well clear of hardscape features, cart paths, and foot traffic areas.

Configuration

•  globe, forward flow
•  ingot brass and stainless steel 

construction

•  1” (25 mm), 11/4” (32 mm),  

1 1/2” (40 mm), 2” (50 mm) 

NPT and BSP models

•  electric actuation
•  pressure regulating

Dimensions

1”  

53/4” H x 5” W 

 

146 mm H x 127 mm W

11/4” 

61/2” H x 6” W 

 

165 mm H x 152 mm W

11/2” 

61/2” H x 6” W 

 

165 mm H x 152 mm W

2” 

71/2” H x 7” W 

 

191 mm H x 178 mm W

Flow Range

1” (25 mm)  

5-40 gpm 

  19-151 

lpm

11/4” (32 mm)  

20-100 gpm 

 

  

76-379 lpm

11/2” (40 mm)  

20-130 gpm 

 

  

76-492 lpm

2” (50 mm)  

30-180 gpm 

  114-681 

lpm

Operating Pressure Range

•  Inlet: 10-220 psi (,69-15,2 bar)
•  Outlet: 5-100 +/- 3 psi  

(,34-6,9 bar +/- ,2 bar)

•  minimum inlet / outlet differential:  

10 psi (,69 bar)

•  burst pressure safety rating:  

750 psi (51,7 bar)

SpikeGuard solenoid

  

(for satellite control systems)

24 VAC, 50/60 Hz

Inrush - 0.12 amps

Holding - 0.10 amps

DC-latching solenoid

  

(for GDC 2-Wire control systems)

momentary low-voltage pulse

Diaphragm

 

double-beaded, fabric-reinforced

Filter screen

 

•  120-mesh stainless steel

•  self-flushing, contamination resistance

Manual Flow Control

adjustable to zero flow

Manual Bleed Screw

enables manual valve operation

bleeds off water internally downstream

EZReg Pressure Regulator

•  compact, precision-dial design

•  regulates during atomatic and  

manual operation

•  serviceable while valve is pressurized

•  poppet valve (Schrader-type) for 

downstream pressure verification

Friction Loss in PSI

GPM

5

10

15

20

30

40

50

60

70

80 100 120 150 170 180

1”

1.75 2.00 2.20 3.10 5.05 7.80

1 1/4”

1.85 2.50 2.70 3.50 4.10 5.60

1 1/2”

2.15 2.45 2.80 3.05 3.80 5.00 6.55

2”

3.05 3.20 2.90 2.95 3.25 3.40 4.50 6.50 10.10 13.45 14.85

Friction Loss in BAR

LPM

,35 ,69 1,0 1,4 2,1 2,8 3,4 4,1 4,8 5,5 6,9 8,3 10,3 11,7 12,4

25 mm

1.21 1.38 1.52 2.14 3.48 5.37

32 mm

1.27 1.72 1.86 2.41 2.82 3.86

40 mm

1.48 1.69 1.93 2.10 2.62 3.45 4.51

50 mm

2.10 2.20 2.00 2.03 2.24 2.34 3.10 4.48 6.96 9.27 10.23