Finishing the Job
Complete the following after each day of use:
•
Connect the hand spray gun to the pump and clean
the machine with clean water; refer to
with the Spray-Hose Attachment (page 97)
.
•
Flush the drilling fluid out of the drilling-fluid pump
with water or antifreeze.
Note:
The drilling-fluid pump may be damaged if
the drilling-fluid dries up in the pump.
•
If the air temperature is below freezing or will
be before the next use, refer to
Drilling-Fluid System for Cold Weather (page 95)
.
•
Add grease to the grease fittings; refer to
the Machine (page 68)
.
•
Install the console covers; refer to
Operator-Controls Covers (page 27)
.
Using the TJC Applicator
Adjusting the Applicator Nozzle
You can adjust the applicator nozzle to spray
thread-joint compound (TJC) either in a fan-shaped
spray or as a stream.
•
For fan-shaped spray—turn the spray valve on the
side of the nozzle horizontal (
).
•
For a stream—turn the spray valve on the side of
the nozzle vertical (
).
g023077
Figure 70
1.
Spray valve—fan-shaped
spray (horizontal)
2.
Spray valve—stream
(vertical)
Adjusting the TJC-spray Volume
To adjust the volume of thread-joint compound that is
delivered by the applicator, complete the following:
1.
Loosen the jam nut on the adjustment bolt
located on top of the TJC-applicator piston
(
).
g218970
Figure 71
1.
Adjustment bolt
3.
TJC-applicator piston
2.
Jam nut
2.
Adjust the bolt as follows:
•
To increase the applied volume of compound,
thread the bolt out (up).
•
To decrease the applied volume of
compound, thread the bolt in (down).
3.
When you have attained the desired application
volume, tighten the jam nut to secure the
adjustment.
63
Summary of Contents for 2226
Page 107: ...Notes ...
Page 108: ......