background image

Lawn Master

TM

 II Landscape Timer

Models: 53805 (4-Zone) & 53806 (6-Zone)
Installation & Programming Guide

English

Spanish

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for 53805

Page 1: ...Lawn MasterTM II Landscape Timer Models 53805 4 Zone 53806 6 Zone Installation Programming Guide English Spanish Downloaded from www Manualslib com manuals search engine...

Page 2: ...E DAY Setup Page 8 WATERING DAYS Setup Page 9 START TIMES Setup Page 10 SET ZONE TIMES Setup Page 11 SEASON ADJUST Setup Page 12 MANUAL STATION Operation Page 12 MANUAL PROGRAM Operation Page 13 Turni...

Page 3: ...the previous menu item Navigate to the next menu item Adjust Increase the selected value Adjust Decrease the selected value 5 Terminal Block RS1 RS2 Sensor AC1 AC2 AC Power COM Valve Common MV Master...

Page 4: ...ied station to run The run times can be set from one minute and up to six hours SEASON ADJUST Select to adjust the program s watering by percentage You can decrease your irrigation system s watering d...

Page 5: ...n sensor optional is installed SENSOR indicates that rain has been detected 7 PROGRAM A B or C Indicates which program is selected 8 Season Adjust Indicates that the automatic programs have been adjus...

Page 6: ...the two screws horizontally Install two screws 5 inches 12 7 cm apart into the wall at eye level Leave the screw extended approximately 1 4 inch 6 mm from the wall to accommodate the controller case I...

Page 7: ...he current time date and scheduled programs are retained IMPORTANT Check the controller s scheduled watering program after every power outage to prevent interruption to your irrigation system s activi...

Page 8: ...sensor switch must be in the OFF position or the jumper wire must be installed Step 1 Remove the controller s lower panel cover to access the sensor terminals Step 2 Route the rain sensor s cable to...

Page 9: ...g solenoid lead from each valve For reference note the wire color code being used for each valve connection and the associated watering station Step 3 Remove the controller s lower panel cover to acce...

Page 10: ...e current month s value Press button to advance to DAY Step 4 With DAY displayed press or to adjust the current day s value Press to advance to AM PM Step 5 With AM or PM flashing press or to select A...

Page 11: ...on watering day To enable a non watering day press or until the desired weekday is flashing Press to enable The icon will be displayed above the active day Step 4 For ODD scheduling press or until ODD...

Page 12: ...ified Step 4 Press or to adjust the time to the desired START TIME For unused start times make sure OFF is displayed OFF is located between 11 45pm and 12 00am Each key press will increase or decrease...

Page 13: ...ep 3 Press or to select the Zone station number 1 6 being modified Step 4 Press or to adjust the desired time duration runtime you want the station to be active Each station can have a runtime of one...

Page 14: ...MANUAL STATION Operation MANUAL STATION operation enables you to activate any station and give a temporary run time duration Only one station can be activated by the MANUAL STATION operation Any run...

Page 15: ...To modify the station run times temporarily press or to select the Station number being modified Press or to adjust the desired run time duration Step 5 Turn the function dial slowly to the RUN positi...

Page 16: ...T set to 0 AC power source is not connected NO AC is displayed Battery is weak or missing Mechanical override Valve s manual bleed is ON Function Dial was rotated too quickly to the RUN position Corre...

Page 17: ...at 0 75A Capacity One Station plus Master Valve or 24 VAC Pump Start Relay Active at one time Maximum Electrical Output 350mA per Station Operating Temperature 32 F to 140 F 0 C to 60 C Storage Temper...

Page 18: ...tion loss the cost of substitute equipment or services required during periods of malfunction or resulting non use property damage or personal injury resulting from installer s negligence Some states...

Page 19: ...art time number being set 3 start times per program Press or to adjust the start time SET ZONE TIMES Place function dial to position Press or to select the station number Press or to adjust the statio...

Page 20: ...18 2007 The Toro Company Consumer Division www toro com Made in China Part Number 373 0445 Rev B 5 Inches 12 7cm Downloaded from www Manualslib com manuals search engine...

Page 21: ...Temporizador para zonas verdes Lawn MasterTM II Modelos 53805 4 zonas y 53806 6 zonas Gu a de instalaci n y programaci n English Spanish Downloaded from www Manualslib com manuals search engine...

Page 22: ...ste de D AS DE RIEGO P gina 9 Ajuste de HORAS DE ARRANQUE P gina 10 Ajuste de TIEMPOS DE RIEGO POR ZONAS P gina 11 Ajuste de RIEGO PORCENTUAL P gina 12 Funci n ESTACI N MANUAL P gina 12 Funci n PROGRA...

Page 23: ...anterior Ir al elemento de men siguiente Ajustar Aumentar el valor seleccionado Ajustar Reducir el valor seleccionado 5 Bloque terminal RS1 y RS2 Sensor AC1 y AC2 Potencia CA COM Cable com n de v lvul...

Page 24: ...ajustarse entre un minuto y seis horas SEASON ADJUST Ajusta porcentualmente el riego de cada programa Puede reducirse el tiempo de riego del sistema al 0 Sistema OFF apagado o aumentar el tiempo de ri...

Page 25: ...ctado lluvia 7 PROGRAM A B o C Indica el programa seleccionado 8 Season Adjust Indica que los programas autom ticos han sido ajustados 9 AM o PM Indica la hora en formato AM ma ana o PM tarde 10 Riego...

Page 26: ...nte los dos tornillos Instale dos tornillos en la pared al nivel de los ojos con una separaci n entre s de cinco pulgadas 12 7 cm Los tornillos deben sobresalir aproximadamente 1 4 pulgada 6 mm de la...

Page 27: ...hora y los programas IMPORTANTE Cada vez que se produzca un corte de energ a el ctrica compruebe el programa de riego del programador para evitar interrupciones en la actividad de su sistema de riego...

Page 28: ...debe estar en la posici n OFF o debe instalarse el cable puente Paso 1 Retire la tapa del panel inferior del programador para tener acceso a los terminales del sensor Paso 2 Lleve el cable del sensor...

Page 29: ...cada v lvula Para su referencia anote el color del cable usado para cada conexi n de v lvula y la estaci n de riego asociada Paso 3 Retire la tapa del panel inferior del programador para tener acceso...

Page 30: ...se para avanzar a DAY Paso 4 Con DAY en pantalla pulse o para ajustar el valor al d a actual Pulse para avanzar a AM PM Paso 5 Con AM o PM parpadeando pulse o para seleccionar AM ma ana o PM tarde Pul...

Page 31: ...riego pulse o hasta que parpadee el d a de la semana deseado Pulse para habilitar ese d a Se mostrar el icono en la pantalla encima del d a activo Paso 4 Para el calendario ODD d as impares pulse o ha...

Page 32: ...ora de arranque deseada Para las horas de arranque sin utilizar aseg rese de que la pantalla muestre OFF deshabilitado OFF est situado entre las horas de 11 45pm y 12 00am Cada pulsaci n adelanta o re...

Page 33: ...na estaci n 1 6 a modificar Paso 4 Pulse o para ajustar el tiempo de riego durante el cual la estaci n debe estar activada El tiempo de riego de cada estaci n puede ajustarse entre un minuto y seis ho...

Page 34: ...ci n manual le permite activar manualmente cualquier estaci n y establecer un tiempo de riego temporal S lo es posible activar una estaci n utilizando la funci n MANUAL STATION Cualquier ajuste del ti...

Page 35: ...temporalmente los tiempos de riego de las estaciones pulse o para seleccionar el n mero de la estaci n a modificar Pulse o para ajustar el tiempo de riego Paso 5 Gire el dial de funciones lentamente...

Page 36: ...si agotada Sobrecontrol mec nico la purga manual de la v lvula est en ON El dial de funciones se gir demasiado r pidamente a la posici n RUN Soluci n Compruebe y cambie el solenoide Compruebe las cone...

Page 37: ...a a 0 75 A Capacidad Una estaci n m s v lvula maestra o rel de arranque de bomba de 24 Vca activa en cualquier momento Temperatura de operaci n 32 F a 140 F 0 C a 60 C Temperatura de almacenamiento 4...

Page 38: ...urante periodos de aver a o la p rdida consiguiente de uso da os materiales o lesiones personales que son el resultado de la negligencia del instalador Algunos estados no permiten exclusiones de da os...

Page 39: ...que por programa a establecer Pulse o para ajustar la hora de arranque Establecer TIEMPOS DE RIEGO Ponga el dial de funciones en la posici n Pulse o para seleccionar el n mero de estaci n Pulse o para...

Page 40: ...18 2007 The Toro Company Divisi n de Consumo www toro com Fabricado en China Pieza N 373 0445 Rev AB 5 pulgadas 12 7 cm Downloaded from www Manualslib com manuals search engine...