Greensmaster 3320/3420
Page 6 -- 23
Electrical System
Fault Code (Lamp Flashes)
Fault Description
4 -- 3
Optional hydraulic oil temperature sensor is faulty (GR3420)
4 -- 4
System voltage to generator and all cutting unit motors is
insufficient (likely a 48V battery problem)
4 -- 5
System voltage to generator and all cutting unit motors is
excessive (e.g. incorrect batteries or charger problem)
4 -- 6
Logic system voltage to generator and all cutting unit motors is
excessive (e.g. incorrect batteries or charger problem)
4 -- 7
Current to console high temperature warning light is excessive (GR3420)
4 -- 9
Generator current is excessive
5 -- 1
Engine alternator voltage output is incorrect
5 -- 2
Engine alternator voltage output is excessive
5 -- 4
Right fuse 2 (7.5 amp) for TEC outputs is faulty
5 -- 5
Right fuse 3 (7.5 amp) for TEC outputs is faulty
5 -- 6
Right fuse 4 (7.5 amp) for TEC outputs is faulty
5 -- 7
Current to leak detector alarm (GR3320) or glow relay (GR3420) is excessive
5 -- 9
48V contactor is faulty (stuck in closed position)
6 -- 2
Generator speed is excessive
6 -- 3
Location ID module is faulty
6 -- 4
Main power relay is faulty (this fault could also indicate that all TEC output 7.5
amp fuses are faulty)
6 -- 6
Controller software in cutting unit motors and/or generator incompatible with
TEC controller
6 -- 7
Current to solenoid coil S1 (lift/lower manifold) is excessive
6 -- 9
Current to 48V contactor coil is excessive
7 -- 1
Current to solenoid coil S2 (lift/lower manifold) is excessive
7 -- 4
Current to solenoid coil S3 (lift/lower manifold) is excessive
7 -- 6
Current to solenoid coil S4 (lift/lower manifold) is excessive
7 -- 8
Current to solenoid coil PRV (mow manifold) is excessive
8 -- 1
Current to start relay is excessive
8 -- 3
CAN--Bus address issue existed
8 -- 4
Current to E--reel enable relay is excessive
8 -- 6
System voltage to #1 cutting unit motor is excessive
(motor will be disabled)
8 -- 7
System voltage to #2 cutting unit motor is excessive
(motor will be disabled)
8 -- 8
System voltage to #3 cutting unit motor is excessive
(motor will be disabled)
8 -- 9
System voltage to generator is excessive
(generator will be disabled)
9 -- 4
System voltage to #1 cutting unit motor is insufficient
(motor will be disabled)
9 -- 5
System voltage to #2 cutting unit motor is insufficient
(motor will be disabled)
9 -- 6
System voltage to #3 cutting unit motor is insufficient
(motor will be disabled)
Elec
trica
l
System
Summary of Contents for Greensmaster 3420 TriFlex
Page 2: ...Greensmaster 3320 3420 This page is intentionally blank ...
Page 4: ...Greensmaster 3320 3420 This page is intentionally blank ...
Page 6: ...Greensmaster 3320 3420 This page is intentionally blank ...
Page 24: ...Greensmaster 3320 Page 3 6 Gasoline Engine This page is intentionally blank ...
Page 38: ...Greensmaster 3420 Page 4 4 Diesel Engine This page is intentionally blank ...
Page 54: ...Greensmaster 3420 Page 4 20 Diesel Engine This page is intentionally blank ...
Page 56: ...Greensmaster 3320 3420 Hydraulic System Page 5 2 This page is intentionally blank ...
Page 150: ...Greensmaster 3320 3420 Hydraulic System Page 5 96 This page is intentionally blank ...
Page 250: ...Greensmaster 3320 3420 Page 6 100 Electrical System This page is intentionally blank ...
Page 277: ...Greensmaster 3320 3420 Page 7 27 Chassis This page is intentionally blank Chassis ...
Page 325: ...Greensmaster 3320 3420 Groomer Page 9 13 This page is intentionally blank Groomer ...
Page 340: ...Greensmaster 3320 3420 Page 10 2 Foldout Drawings This page is intentionally blank ...
Page 347: ...Page 10 9 This page is intentionally blank ...
Page 356: ...Page 10 18 E Reels Wire Harness Drawing Greensmaster 3320 3420 Serial Number Below 312000000 ...
Page 358: ...Page 10 20 E Reels Wire Harness Drawing Greensmaster 3320 3420 Serial Number Above 312000000 ...
Page 360: ...Page 10 22 This page is intentionally blank ...