Fan Speed Switch (Machines with Operator Cab)
g243778
Figure 142
1.
Cab headliner (air/heat panel)
2.
Fan speed switch
The fan speed switch is located in the cab headliner (
). The switch is
used to select the fan speed (off, low, medium, or high).
Testing the Fan Speed Switch
1. Park the machine on a level surface, lower the cutting deck, and shut off the
engine. Remove the key from the key switch.
2. To access the switch, remove the roof from the top of the cab; refer to
.
3. Remove the air/heat panel from the cab headliner.
4. Disconnect the machine wire harness connector from the fan speed switch.
g242792
Figure 143
Back of Switch
5. The switch terminals are identified in
and the circuitry of the
switch is shown in the
Circuit Logic Table (page 6–43)
. With the use of a
multimeter (ohms setting), test the switch functions to determine if continuity
exists between only the terminals listed for each switch position. Check the
continuity between the switch terminals.
Electrical System: Testing the Electrical Components
Page 6–42
Groundsmaster
®
3280-D/3320
05138SL Rev B
Summary of Contents for Groundsmaster 3280-D
Page 4: ...NOTES Revision History Page 4 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 10: ...Preface Page 10 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 56: ...Gasoline Engine Service and Repairs Page 3 22 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 84: ...Diesel Engine Service and Repairs Page 4 28 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 228: ...Hydraulic System Service and Repairs Page 5 144 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 430: ...PTO System Service and Repairs Page 9 12 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 466: ...Operator Cab Service and Repairs Page 11 16 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 470: ...Foldout Drawings Page A 4 Groundsmaster 3280 D 3320 05138SL Rev B ...
Page 508: ......